undo default interval
View
OSPF view
Parameter
seconds: Default interval for importing external routes. Its unit is second and
the value ranges from 1 to 2147483647. By default, the interval for OSPF to
import external routes is 1 second.
Description
Using the default interval command, you can configure the default interval for
OSPF to import external routes. Using the undo default interval command, you can
restore the default value of the default interval of importing external routes.
Because OSPF can import the external routing information and broadcast it to the
entire autonomous system, it is necessary to specify the default interval for the
protocol to import external routes.
Example
Specify the default interval for OSPF to import external routes as 10 seconds.
[3Com-ospf-1] default interval 10
default limit
Syntax
default limit routes
undo default limit
View
OSPF view
Parameter
routes: Default value to the imported external routes in a unit time, ranging
from 200 to 2147483647. By default, the value is 1000.
Description
Using the default limit command, you can configure default value of maximum
number of imported routes. Using the undo default limit command, you can
restore the default value.
OSPF can import external route information and broadcast them to the whole
autonomous system, so it is necessary to regulate the default value of external
route information imported in one process.
For the related command, see default interval.
Example
Specify the default value of OSPF importing external routes as 200.
[3Com-ospf-1] default limit 200
default tag