Description
Using the llc2 timer busy command, you can configure the LLC2 BUSY time. Using
the undo llc2 timer busy command, you can restore the default value of the LLC2
BUSY time.
By default, the LLC2 BUSY time is 300ms.
The LLC2 BUSY time refers to the waiting time before repolling a busy station.
Example
Configure the LLC2 BUSY time as 200ms.
[3Com-Ethernet1/0/0] llc2 timer busy 200
Syntax
llc2 timer poll mseconds
undo llc2 timer poll
View
Ethernet Interface view
Parameter
mseconds: LLC2 P/F waiting time, ranging from 1 to 60000ms.
Description
Using the llc2 timer poll command, you can configure the P/F waiting time of the
LLC2. Using the undo llc2 timer poll command, you can restore the default value
of the LLC2 P/F waiting time.
By default, the LLC2 P/F waiting time is 5000ms.
The LLC2 P/F waiting time refers to the time of waiting for the acknowledgement
frame after the frame P is sent.
Example
Configure the LLC2 P/F waiting time as 2000ms.
[3Com-Ethernet1/0/0] llc2 timer poll 2000
Syntax
llc2 timer reject mseconds
undo llc2 timer reject
View
Ethernet Interface view
Parameter
mseconds: The LLC2 REJ time, ranging from 1 to 60000ms.
Description
Using the llc2 timer reject command, you can configure the REJ time of the LLC2.
Using the undo llc2 timer reject command, you can restore the default value of the
LLC2 REJ time.