388
C
4: L
L
P
HAPTER
INK
AYER
ROTOCOL
View
Interface view
Parameter
minutes: Maximum idle time of SVC in minutes, and its value ranges from 0 to
255.By default, this value is 0.
Description
Using the x25 timer idle command, you can set the maximum idle time of the SVC
on the interface. Using the undo x25 timer idle command, you can restore its
default value.
When a SVC stays idle (no data transmission) for a period (the period length is
decided by the parameter), the router will clear this SVC automatically. If this
parameter is set to 0, this SVC will be reserved no matter how long it stays idle.
The configuration of this parameter will affect all the SVCs on this X.25 interface.
Also users can set the maximum idle time for a SVC attached to this address
mapping through the option in the command x25 map.
For PVC or the established SVC for X.25 switching, the command will be disabled.
For the related command, see x25 map.
Example
Set the maximum idle time of the SVC on the interface Serial 0/0/0 to 10 minutes.
[3Com-Serial0/0/0] x25 timer idle 10
x25 timer tx0
Syntax
x25 timer tx0 seconds
undo x25 timer tx0
View
Interface view
Parameter
seconds: Delay time for the X.25 restarting timer in seconds. It ranges 0 to 1000.
By default, the delay on the X.25 DTE restarting timer is 180 seconds and that on
the DCE timer is 60 seconds.
Description
Using the x25 timer tx0 command, you can set the restart/retransmission timer
delay for DTE (or DCE). Using the undo x25 timer tx0 command, you can restore
their default values.