3Com 3031 Command Reference Manual page 378

3com 3031: reference guide
Hide thumbs Also See for 3031:
Table of Contents

Advertisement

378
C
4: L
L
P
HAPTER
INK
AYER
x25 queue-length
ROTOCOL
PVC number is 1, the PVC section will be disabled naturally. The following table
shows some typical PVC sections.
Table 21 PVC channel section of some typical configurations
Incoming-only
channel range
Two-way channel range
[0, 0]
[1, 1024]
[0, 0]
[10, 24]
[1, 10]
[15, 30]
[5, 10]
[15, 25]
[0, 0]
[0, 0]
[0, 0]
[0, 0]
Detailed explanations of PVC options are follows:
broadcast: Forward broadcast packet to the peer PVC.
encapsulation-type: Encapsulation type, which may be nonstandard, ietf,
multi-protocol and snap.
packet-size input-packet output-packet: Specifies the maximum receiving
packet length and maximum sending packet length. The length is counted in
byte, which must range from 16 to 4096 (including 16 and 4096), and must be
the integer power of 2.
window-size input-window-size output-window-size: Specifies the receiving
window and transmitting window sizes of the VC, which range between 1 and
the number that is 1 less than the modulus of the X.25 interface where the
address mapping exists (including 1 and modulus minus 1).
For the related commands, see display x25, x25 map.
Example
Configure the link layer protocol on the interface Serial0/0/0 to X.25, enable PVC
channel section, and set two VCs.
[3Com] interface serial 0/0/0
[3Com-Serial0/0/0] link-protocol x25
[3Com-Serial0/0/0] x25 vc-range bi-channel 8,102 4
[3Com-Serial0/0/0] x25 pvc 2 ip 202.38.168.1 x121-address 20112451
broadcast packet-size 512 512
[3Com-Serial0/0/0] x25 pvc 6 ip 202.38.168.3 x121-address 20112453
broadcast window-size 5 5
Syntax
x25 queue-length queue-length
undo x25 queue-length
View
Interface view
Outgoing-only channel range
[0, 0]
[0, 0]
[0, 0]
[30, 32]
[20, 45]
[0, 0]

Advertisement

Table of Contents
loading

Table of Contents