VLT AutomationDrive FC 301/302
Programming Guide
4.1.13 Value, Step by Step
Certain parameters can be changed step by step. This applies to:
•
Parameter 1-20 Motor Power [kW].
•
Parameter 1-22 Motor Voltage.
•
Parameter 1-23 Motor Frequency.
The parameters are changed both as a group of numeric data values and as numeric data values that are infinitely varying.
4.1.14 Readout and Programming of Indexed Parameters
Parameters are indexed when placed in a rolling stack. Parameter 15-30 Fault Log: Error Code to parameter 15-32 Alarm Log: Time
contain a fault log, which can be read out. Select a parameter, press [OK], and press the [▵] [▿] keys to scroll through the value log.
4.1.14.1 Changing Values of Indexed Parameters
Change parameter 3-10 Preset Reference as an example.
Procedure
1.
Select the parameter, press [OK], and press [▵] [▿] to scroll through the indexed values.
2.
To change the parameter value, select the indexed value and press [OK].
3.
Change the value by pressing [▵] [▿].
4.
Press [OK] to accept the new setting.
5.
Press [Cancel] to abort. Press [Back] to leave the parameter.
4.2 Numerical Local Control Panel
The following instructions are valid for the numerical LCP (LCP 101).
1
Status
2
Menu
On
3
Warn.
Alarm
Hand
4
Off
On
Illustration 21: NLCP
The NLCP is divided into 4 functional groups:
30 | Danfoss A/S © 2022.12
Setup
Quick
Main
Setup
Menu
OK
Auto
Reset
On
How to Program
AU275636650261en-000101 / 130R0334