VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[30]
External Can
[35]
Option A fast
[37]
Option C0 fast
5.31 Parameter Group 42-** Safety Functions
The parameters in this parameter group are available when a safety option is installed in the drive. For information about the safety-
related parameters, see the intallation guides for the safety options:
VLT® Safety Option MCB 150/151 Installation Guide
VLT® Safety Options MCB 152 Installation Guide
5.31.1 42-0* Speed Performance
Parameter 42-00 Speed Deviation Timer
Table 1370: Parameter 42-00 Speed Deviation Timer
42-00 Speed Deviation Timer
Default value: 10 ms
Conversion index: -3
Enter the time for which a speed deviation above 120 RPM between estimated and measured speed is allowed.
Parameter 42-01 Fast Ramp
Table 1371: Parameter 42-01 Fast Ramp
42-01 Fast Ramp
Default value: [0] No
Conversion index: -
Option
[0]*
[1]
5.31.2 42-1* Speed Monitoring
Parameter 42-10 Measured Speed Source
Table 1372: Parameter 42-10 Measured Speed Source
42-10 Measured Speed Source
Default value: Size related
Conversion index: -
668 | Danfoss A/S © 2022.12
Description
This option is only available in FC 302.
This option is only available in FC 302.
Parameter type: Range, 10 - 5000 ms
Data type: Uint16
Parameter type: Option
Data type: Uint8
Name
No
Yes
Parameter type: Option
Data type: Uint8
N O T I C E
N O T I C E
Setup: 2 setups
Change during operation: False
Setup: 2 setups
Change during operation: False
Description
Setup: 1 setup
Change during operation: False
AU275636650261en-000101 / 130R0334
Parameter Descriptions