How to Program

2.1.12 Changing a Data Value

2
2
If the selected parameter shows a numeric data value,
change the selected data value with the [
keys and the [
move the cursor horizontally.
Illustration 2.17 Changing a Data Value
Press the [
] [
increases the data value, and [
Place the cursor on the value to save and press [OK].
Illustration 2.18 Saving a Data Value
2.1.13 Infinitely Variable Change of
Numeric Data Value
If the selected parameter shows a numeric data value,
select a digit with [
Illustration 2.19 Selecting a Digit
Change the selected digit infinitely variably with [
The cursor indicates the selected digit. Place the cursor on
the digit to save and press [OK].
20
] [
] navigation keys. Press [
113 RPM
1.78 A
Load depen. setting
1 - 60 Low speed load
compensation
100%
] keys to change the data value. [
] decreases the data value.
729RPM
6.21A
Load depen. setting
1 - 60 Low speed load
compensation
6
1 0%
] [
].
635 RPM
0.44 A
Start Adjustments
1 - 71 Start Delay
00.0s
Danfoss A/S © 10/2018 All rights reserved.
®
VLT
AutomationDrive FC 301/302
] [
] navigation
] [
] keys to
Illustration 2.20 Saving
1(1)
1- 6*

2.1.14 Value, Step by Step

Certain parameters can be changed step by step. This
applies to:
The parameters are changed both as a group of numeric
]
data values and as numeric data values that are infinitely
varying.
2.1.15 Readout and Programming of
1(1)
1- 6*
Parameters are indexed when placed in a rolling stack.
Parameter 15-30 Fault Log: Error Code to
parameter 15-32 Alarm Log: Time contain a fault log, which
can be read out. Select a parameter, press [OK], and press
the [
] [
For example, parameter 3-10 Preset Reference is changed as
follows:
1.
2.
3.
4.
1 (1)
1- 7*
5.
2.1.16 How to Program on the Numerical
The following instructions are valid for the numerical LCP
(LCP 101).
] [
].
The control panel is divided into 4 functional groups:
957RPM
11.58A
Start Adjustments
1-71 High starting torque time
0. s
4
Parameter 1-20 Motor Power [kW].
Parameter 1-22 Motor Voltage.
Parameter 1-23 Motor Frequency.
Indexed Parameters
] keys to scroll through the value log.
Select the parameter, press [OK], and press [
to scroll through the indexed values.
To change the parameter value, select the
indexed value and press [OK].
Change the value by pressing [
Press [OK] to accept the new setting.
Press [Cancel] to abort. Press [Back] to leave the
parameter.
Local Control Panel
Numerical display.
Menu keys and indicator lights - changing
parameters and switching between display
functions.
Navigation keys and indicator lights.
Operation keys and indicator lights.
1 (1)
1-7*
] [
]
] [
].
MG33MP02