VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[100]
RS Flipflop 6
[101]
RS Flipflop 7
[102]
Relay 1
[103]
Relay 2
[104]
Relay 3
[105]
Relay 4
[106]
Relay 5
[107]
Relay 6
[108]
Relay 7
[109]
Relay 8
[110]
Relay 9
[212]
Emergency mode
[222]
Homing OK
[223]
On target
[224]
Position error
[225]
Position limit
[226]
Touch on target
Danfoss A/S © 2022.12
Description
See parameter group 13-1* Comparators.
See parameter group 13-1* Comparators.
X47/VLT® Extended Relay Card MCB 113.
X47/VLT® Extended Relay Card MCB 113.
X47/VLT® Extended Relay Card MCB 113.
X47/VLT® Extended Relay Card MCB 113.
X34/VLT® Relay Card MCB 105.
X34/VLT® Relay Card MCB 105.
X34/VLT® Relay Card MCB 105.
This option is only available with software version 48.2X or newer.
Homing is completed with the selected homing function (parameter 17-80 Homing Function).
This option is only available with software version 48.2X or newer.
Positioning is completed and the on target signal is sent when the actual position is within
parameter 3-05 On Reference Window for the duration of parameter 3-09 On Target Time and
the actual speed does not exceed parameter 3-05 On Reference Window.
This option is only available with software version 48.2X or newer.
The position error exceeds the value in parameter 4-71 Maximum Position Error for the time
set in parameter 4-72 Position Error Timeout.
This option is only available with software version 48.2X or newer.
The position is outside the limits set in parameter 3-06 Minimum Position and parameter 3-07
Maximum Position.
This option is only available with software version 48.2X or newer.
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
AU275636650261en-000101 / 130R0334 | 407
Parameter Descriptions