Parameter 23-02 OFF Time
Table 1023: Parameter 23-02 OFF Time
23-02 OFF Time
Default value: Size related
Conversion index: 0
Sets the OFF time for the desired action.
The drive has no back-up of the clock function. The set date/time resets to default (2000-01-01 00:00) after a power-down unless
a real-time clockmodule with back-up is installed. In parameter 0-79 Clock Fault, it is possible to program a warning if the clock has
not been set properly, for example after a power-down.
Parameter 23-03 OFF Action
Table 1024: Parameter 23-03 OFF Action
23-03 OFF Action
Default value: [1] No action
Conversion index: -
Danfoss A/S © 2022.12
Name
Set digital out A low
Set digital out B low
Set digital out C low
Set digital out D low
Set digital out E low
Set digital out F low
Set digital out A high
Set digital out B high
Set digital out C high
Set digital out D high
Set digital out E high
Set digital out F high
Reset counter A
Reset counter B
Counter A (up)
Counter A (down)
Counter B (up)
Counter B (down)
Parameter type: Range, 0 - 0, Array [10]
Data type: TimeOfDayWoDate
N O T I C E
Parameter type: Option, Array [10]
Data type: Uint8
Parameter Descriptions
Description
Setup: 2 setups
Change during operation: True
Setup: 2 setups
Change during operation: True