VLT AutomationDrive FC 301/302
Programming Guide
Parameter 5-63 Terminal 29 Pulse Output Variable
Table 377: Parameter 5-63 Terminal 29 Pulse Output Variable
5-63 Terminal 29 Pulse Output Variable
Default value: Size related
Conversion index: –
Option
Name
[0]
No operation
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[51]
MCO controlled
[97]
Reference after ramp
[99]
Virtual master speed
[100]
Output frequency
[101]
Reference
[102]
Feedback
[103]
Motor current
[104]
Torque rel to limit
[105]
Torque related to rated
[106]
Power
[107]
Speed
[108]
Torque
[109]
Max out freq
[119]
Torque % lim
Parameter 5-65 Pulse Output Max Freq #29
Table 378: Parameter 5-65 Pulse Output Max Freq #29
5-65 Pulse Output Max Freq #29
Default value: Size related
Conversion index: 0
Danfoss A/S © 2022.12
Parameter type: Option
Data type: Uint8
Description
Select the display output for terminal 27.
This option is only available with software version 48.XX.
Actual speed reference after the ramp. Use this output as master signal for speed synchroni-
zation of follower drives. The reference is set in parameter 16-48 Speed Ref. After Ramp [RPM].
This option is only available with software version 48.XX.
Virtual master signal for controlling the speed or position of the followers.
Parameter type: Range, 0 - 110000 Hz
Data type: Uint32
Setup: All setups
Change during operation: True
N O T I C E
N O T I C E
Setup: All setups
Change during operation: True
AU275636650261en-000101 / 130R0334 | 223