Danfoss VLT AutomationDrive FC 301 Programming Manual page 520

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Parameter 17-34 HIPERFACE Baudrate
Table 923: Parameter 17-34 HIPERFACE Baudrate
17-34 HIPERFACE Baudrate
Default value: [4] 9600
Conversion index: -
This parameter cannot be adjusted while the motor is running.
Select the baud rate of the attached encoder. The parameter is only accessible when parameter 17-20 Protocol Selection is set to [1]
HIPERFACE.
Option
[0]
[1]
[2]
[3]
[4]*
[5]
[6]
5.17.4 17-4* Fieldbus Reference 2
Parameter 17-40 Fieldbus Sync. Delta
Table 924: Parameter 17-40 Fieldbus Sync. Delta
17-40 Fieldbus Sync. Delta
Default value: 0
Parameter type: Range, -2147483648 - 2147483647
Conversion index: 0
Data type: Int32
This parameter is only available with software version 48.XX.
Shows the fieldbus synchronizing master position change = master speed when transferred by PCD from fieldbus master.
Parameter 17-41 Fieldbus Profile Velocity
Table 925: Parameter 17-41 Fieldbus Profile Velocity
17-41 Fieldbus Profile Velocity
Default value: 0
Conversion index: 0
This parameter is only available with software version 48.XX.
Velocity reference for the profile generator in positioning mode or when using Mode of operation and Profile ositioning mode.
520 | Danfoss A/S © 2022.12
Parameter type: Option
Data type: Uint8
N O T I C E
Name
600
1200
2400
4800
9600
19200
38400
N O T I C E
Parameter type: Range, 0 - 2147483647 pu/s
Data type: Int32
N O T I C E
Setup: All setups
Change during operation: False
Description
Setup: 1 setup
Change during operation: True
Setup: 1 setup
Change during operation: True
AU275636650261en-000101 / 130R0334
Parameter Descriptions