Danfoss VLT AutomationDrive FC 301 Programming Manual page 595

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[0]*
No soft changing
[1]
Encoder soft changing enable
[2]
Soft zero setting enable
[4]
Encoder soft changing and soft zero enable
Parameter 32-44 Enc.1 Node ID
Table 1138: Parameter 32-44 Enc.1 Node ID
32-44 Enc.1 Node ID
Default value: 127
Conversion index: 0
Enter the node ID for the feedback CAN encoder.
Parameter 32-45 Enc.1 CAN Guard
Table 1139: Parameter 32-45 Enc.1 CAN Guard
32-45 Enc.1 CAN Guard
Default value: [0] Off
Conversion index: -
Select if the feedback CAN encoder guardians should be off or on.
Option
[0]*
[1]
5.25.3 32-5* Feedback Source
Parameter 32-50 Source Slave
Table 1140: Parameter 32-50 Source Slave
32-50 Source Slave
Default value: [2] Encoder 2 X55
Conversion index: -
Option
[1]
[2]*
[3]
Danfoss A/S © 2022.12
Parameter type: Range, 1 - 127
Data type: Uint8
Parameter type: Option
Data type: Uint8
Name
Off
On
Parameter type: Option
Data type: Uint8
Name
Encoder 1 X56
Encoder 2 X55
Motor control
Setup: 2 setups
Change during operation: True
Setup: 2 setups
Change during operation: True
Description
Setup: 2 setups
Change during operation: True
Description
AU275636650261en-000101 / 130R0334 | 595
Parameter Descriptions
Description