Danfoss VLT AutomationDrive FC 301 Programming Manual page 163

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Dotted
Parameter 4-44 Motor Speed Monitor Max
line
Option
Name
[0]
Disabled
[1]
Warning
[2]
Trip
[3]
Jog
[4]
Freeze output
[5]
Max speed
[6]
Switch to open loop
[7]
Select setup 1
[8]
Select setup 2
[9]
Select setup 3
[10]
Select setup 4
[11]
Stop & trip
[12]
Trip/warning
[13]
Trip/catch
Parameter 4-44 Motor Speed Monitor Max
Table 287: Parameter 4-44 Motor Speed Monitor Max
4-44 Motor Speed Monitor Max
Default value: 300 RPM
Conversion index: 67
Only available in flux control principle.
Enter the maximum allowable speed deviation between the actual mechanical shaft speed and the value in parameter 16-48 Speed
Ref. After Ramp [RPM].
Parameter 4-45 Motor Speed Monitor Timeout
Table 288: Parameter 4-45 Motor Speed Monitor Timeout
4-45 Motor Speed Monitor Timeout
Default value: 0.1 s
Conversion index: -2
Danfoss A/S © 2022.12
Description
The drive reports warning 101, Speed monitor when the speed is outside the limit.
The drive trips and reports alarm 101, Speed monitor.
The drive reports alarm 101, Speed monitor in running mode and warning 101, Speed monitor in
stop or coast mode. This option is only available in closed-loop operation.
Select when there is a need to catch a load, for example when mechanical braking fails. This op-
tion is available in closed loop only. The drive trips and reports alarm 101, Speed monitor in run-
ning mode. In stop mode, the drive catches the flying load and reports warning 101, Speed moni-
tor. In catch mode, the drive applies holding torque to control the 0 speed on a potentially mal-
functioning brake (closed loop). To exit this mode, send a new start signal to the drive. A coast or
Safe Torque Off also terminates the function.
Parameter type: Range, 10 - 500 RPM
Data type: Uint16
N O T I C E
Parameter type: Range, 0 - 60 s
Data type: Uint16
Parameter Descriptions
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True
AU275636650261en-000101 / 130R0334 | 163