VLT AutomationDrive FC 301/302
Programming Guide
Parameter 18-14 Parameter Index
Table 975: Parameter 18-14 Parameter Index
18-14 Parameter Index
Default value: 0 N/A
Conversion index: -
This parameter shows the index of the parameter which was changed.
Parameter 18-15 Change Time
Table 976: Parameter 18-15 Change Time
18-15 Change Time
Default value: Size related
Conversion index: 0
Shows the date and time stamp when a parameter was most recently changed. It is recommended to set the time and date in the
drive to ensure the right time is logged.
Parameter 18-16 Operating Hours
Table 977: Parameter 18-16 Operating Hours
18-16 Operating Hours
Default value: 0
Conversion index: 0
Shows operating hours of the drive at the instance when the parameter was changed.
Parameter 18-17 Running Hours
Table 978: Parameter 18-17 Running Hours
18-17 Running Hours
Default value: 0
Conversion index: 0
Shows running hours of the motor when the parameter is changed.
Parameter 18-18 Value Before Change as Integer
Table 979: Parameter 18-18 Value before change as Integer
18-18 Value before change as Integer
Default value: 0
Parameter type: Range, -2147483648 - 2147483647, Array [10]
Conversion index: 0
Data type: Int32
Shows the previous value of the parameter as integer, without scaling or unit conversion. The parameter only shows integer data.
Parameter 18-19 Value Before Change
Table 980: Parameter 18-19 Value Before Change
18-19 Value Before Change
Default value: Size related
Conversion index: 0
Shows the previous value of the parameter with units. Only applicable for integer values.
540 | Danfoss A/S © 2022.12
Parameter type: Range, 0 - 0xFFFF N/A, Array [10]
Data type: Uint16
Parameter type: Range, 0 - 0, Array [10]
Data type: TimeOfDay
Parameter type: Range, 0 - 2147483647, Array [10]
Data type: Uint32
Parameter type: Range, 0 - 2147483647, Array [10]
Data type: Uint32
Parameter type: Range, 0-30, Array [10]
Data type: VisStr[30]
Parameter Descriptions
4-setup: All set-ups
Change during operation: False
4-setup: All set-ups
Change during operation: False
4-setup: All set-ups
Change during operation: False
4-setup: All set-ups
Change during operation: False
4-setup: All set-ups
Change during operation: False
4-setup: All set-ups
Change during operation: False