VLT AutomationDrive FC 301/302
Programming Guide
Parameter 16-36 Inv. Nom. Current
Table 854: Parameter 16-36 Inv. Nom. Current
16-36 Inv. Nom. Current
Default value: Size related
Conversion index: -2
View the inverter nominal current, which must match the nameplate data on the connected motor. The data is used for calculation
of torque, motor overload protection, and so on.
Parameter 16-37 Inv. Max. Current
Table 855: Parameter 16-37 Inv. Max. Current
16-37 Inv. Max. Current
Default value: Size related
Conversion index: -2
View the inverter maximum current, which must match the nameplate data on the connected motor. The data is used for calcula-
tion of torque, motor overload protection, and so on.
Parameter 16-38 SL Controller State
Table 856: Parameter 16-38 SL Controller State
16-38 SL Controller State
Default value: 0
Conversion index: 0
View the state of the event under execution by the SL controller.
Parameter 16-39 Control Card Temp.
Table 857: Parameter 16-39 Control Card Temp.
16-39 Control Card Temp.
Default value: 0 °C
Conversion index: 100
View the temperature on the control card, stated in °C.
Parameter 16-40 Logging Buffer Full
Table 858: Parameter 16-40 Logging Buffer Full
16-40 Logging Buffer Full
Default value: [0] No
Conversion index: -
View whether the logging buffer is full (see parameter group 15-1* Data Log Settings). The logging buffer is never full when parame-
ter 15-13 Logging Mode is set to [0] Log always.
Option
[0]*
[1]
Danfoss A/S © 2022.12
Parameter type: Range, 0.01 - 10000 A
Data type: Uint32
Parameter type: Range, 0.01 - 10000 A
Data type: Uint32
Parameter type: Range, 0 - 100, Array [4]
Data type: Uint8
Parameter type: Range, 0 - 100 °C
Data type: Uint8
Parameter type: Option
Data type: Uint8
Name
No
Yes
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: True
Description
AU275636650261en-000101 / 130R0334 | 503