Danfoss VLT AutomationDrive FC 301 Programming Manual page 312

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Manufacturer-specific system ID.
Parameter 9-22 Telegram Selection
Table 548: Parameter 9-22 Telegram Selection
9-22 Telegram Selection
Default value: [100] None
Conversion index: –
Select a standard PROFIBUS telegram configuration for the drive as an alternative to the freely configurable telegrams in parameter
9-15 PCD Write Configuration and parameter 9-16 PCD Read Configuration.
Option
[1]
[100]*
[101]
[102]
[103]
[104]
[105]
[106]
[107]
[108]
[200]
[202]
Parameter 9-23 Parameters for Signals
Table 549: Parameter 9-23 Parameters for Signals
9-23 Parameters for Signals
Default value: [0] None
Conversion index: –
This parameter contains a list of signals available for selection in parameter 9-15 PCD Write Configuration and parameter 9-16 PCD
Read Configuration.
Option
Name
[0]*
None
[109]
Mode of operation
[302]
Minimum reference
[303]
Maximum reference
[312]
Catch up/slow down value
[321]
Touch target
312 | Danfoss A/S © 2022.12
Parameter type: Option
Data type: Uint8
Name
Standard telegram 1
None
PPO 1
PPO 2
PPO 3
PPO 4
PPO 5
PPO 6
PPO 7
PPO 8
Custom telegram 1
Custom telegram 3
Parameter type: Option
Data type: Uint16
Parameter Descriptions
Setup: 1 setup
Change during operation: True
Description
Setup: All setups
Change during operation: True
Description
AU275636650261en-000101 / 130R0334