A
B
Illustration 68: Encoder Rotation Direction
Parameter 5-70 Term 32/33 Pulses Per Revolution
Table 381: Parameter 5-70 Term 32/33 Pulses Per Revolution
5-70 Term 32/33 Pulses Per Revolution
Default value: 1024
Conversion index: 0
Set the resolution of the encoder connected to terminal 32/33 in pulses per revolution.
Parameter 5-71 Term 32/33 Encoder Direction
Table 382: Parameter 5-71 Term 32/33 Encoder Direction
5-71 Term 32/33 Encoder Direction
Default value: [0] Clockwise
Conversion index: –
This parameter cannot be adjusted while the motor is running.
Change the detected encoder rotation direction without changing the wiring to the encoder.
Option
Name
[0]*
Clockwise
[1]
Counter clock-
wise
Parameter 5-72 Term 32/33 Encoder Type
Table 383: Parameter 5-72 Term 32/33 Encoder Type
5-72 Term 32/33 Encoder Type
Default value: [0] Quadrature A/B format
Conversion index: –
226 | Danfoss A/S © 2022.12
1
2
Parameter type: Range, 1 - 4096
Data type: Uint16
Parameter type: Option
Data type: Uint8
N O T I C E
Description
Sets channel A 90° (electrical degrees) behind channel B upon clockwise rotation of the encoder
shaft.
Sets channel A 90° (electrical degrees) ahead of channel B upon clockwise rotation of the encoder
shaft.
Parameter type: Option
Data type: Uint8
Parameter Descriptions
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
AU275636650261en-000101 / 130R0334