VLT AutomationDrive FC 301/302
Programming Guide
Bit
Output/Relay
22
Option C relay 7 output terminal
23
Option C relay 8 output terminal
21–31
Reserved for future terminals
Parameter 5-93 Pulse Out #27 Bus Control
Table 391: Parameter 5-93 Pulse Out #27 Bus Control
5-93 Pulse Out #27 Bus Control
Default value: 0%
Conversion index: -2
Set the output frequency transferred to output terminal 27 when the terminal is configured as [45] Bus Controlled in parameter 5-60
Terminal 27 Pulse Output Variable.
Parameter 5-94 Pulse Out #27 Timeout Preset
Table 392: Parameter 5-94 Pulse Out #27 Timeout Preset
5-94 Pulse Out #27 Timeout Preset
Default value: 0%
Conversion index: -2
Set the output frequency transferred to output terminal 27 when the terminal is configured as [48] Bus Ctrl Timeout in parameter
5-60 Terminal 27 Pulse Output Variable and a timeout is detected.
Parameter 5-95 Pulse Out #29 Bus Control
Table 393: Parameter 5-95 Pulse Out #29 Bus Control
5-95 Pulse Out #29 Bus Control
Default value: 0%
Conversion index: -2
Set the output frequency transferred to output terminal 29 when the terminal is configured as [45] Bus Controlled in parameter 5-63
Terminal 29 Pulse Output Variable.
Parameter 5-96 Pulse Out #29 Timeout Preset
Table 394: Parameter 5-96 Pulse Out #29 Timeout Preset
5-96 Pulse Out #29 Timeout Preset
Default value: 0%
Conversion index: -2
Set the output frequency transferred to output terminal 29 when the terminal is configured as [48] Bus Ctrl Timeout in parameter
5-63 Terminal 29 Pulse Output Variable and a timeout is detected.
Parameter 5-97 Pulse Out #X30/6 Bus Control
Table 395: Parameter 5-97 Pulse Out #30/6 Bus Control
5-97 Pulse Out #30/6 Bus Control
Default value: 0%
Conversion index: -2
230 | Danfoss A/S © 2022.12
Parameter type: Range, 0 - 100%
Data type: N2
Parameter type: Range, 0 - 100%
Data type: Uint16
Parameter type: Range, 0 - 100%
Data type: N2
Parameter type: Range, 0 - 100%
Data type: Uint16
Parameter type: Range, 0 - 100%
Data type: N2
Parameter Descriptions
Setup: All setups
Change during operation: True
Setup: 1 setup
Change during operation: True
Setup: All setups
Change during operation: True
Setup: 1 setup
Change during operation: True
Setup: All setups
Change during operation: True
AU275636650261en-000101 / 130R0334