VLT AutomationDrive FC 301/302
Programming Guide
Enter a text which can be viewed in the graphical display by selecting [39] Display Text 3 in
Parameter 0-20 Display Line 1 Small
Parameter 0-21 Display Line 1.2 Small
Parameter 0-22 Display Line 1.3 Small
Parameter 0-23 Display Line 2 Large
Parameter 0-24 Display Line 3 Large

5.1.5 0-4* LCP Keypad

Enable, disable, and password protect individual keys on the LCP.
Parameter 0-40 [Hand On] Key on LCP
Table 28: Parameter 0-40 [Hand On] Key on LCP
0-40 [Hand On] Key on LCP
Default value: [1] Enabled
Conversion index: –
Option
Name
[0]
Disabled
[1]*
Enabled
[2]
Password
[3]
Hand Off/On
[4]
Hand Off/On w.
Passw.
[9]
Enabled, ref=0
Parameter 0-41 [Off] Key on LCP
Table 29: Parameter 0-41 [Off] Key on LCP
0-41 [Off] Key on LCP
Default value: [1] Enabled
Conversion index: –
Option
Name
Description
[0]
Disabled
Avoids accidental stop of the drive.
[1]*
Enabled
[2]
Password
Avoids unauthorized stop. If parameter 0-41 [Off] Key on LCP is included in the Quick Menu, then define the
password in parameter 0-65 Personal Menu Password.
54 | Danfoss A/S © 2022.12
Parameter type: Option
Data type: Uint8
Description
No effect when [Hand On] is pressed. Select [0] Disabled to avoid accidental start of the drive in
hand-on mode.
The LCP switches to hand-on mode directly when [Hand On] is pressed.
After pressing [Hand On] a password is required. If parameter 0-40 [Hand on] Key on LCP is included
in My Personal Menu, define the password in parameter 0-65 Personal Menu Password. Otherwise
define the password in parameter 0-60 Main Menu Password.
When [Hand On] is pressed once, the LCP switches to Off mode. When pressed again, the LCP
switches to hand-on mode.
Same as option [3] Hand Off/On but a password is required (see option [2] Password).
Parameter type: Option
Data type: Uint8
Parameter Descriptions
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True
AU275636650261en-000101 / 130R0334