If [0] Full access is selected, parameter 0-60 Main Menu Password, parameter 0-65 Personal Menu Password, and parameter 0-66 Access
to Personal Menu w/o Password are ignored.
A more complex password protection is available for OEMs upon request.
Parameter 0-65 Personal Menu Password
Table 38: Parameter 0-65 Personal Menu Password
0-65 Personal Menu Password
Default value: 200
Conversion index: 0
Define the password for access to the Quick Menu via the [Quick Menu] key. If parameter 0-66 Access to Personal Menu w/o Password
is set to [0] Full access, this parameter is ignored.
Parameter 0-66 Access to Personal Menu w/o Password
Table 39: Parameter 0-66 Access to Personal Menu w/o Password
0-66 Access to Personal Menu w/o Password
Default value: [0] Full access
Conversion index: –
If parameter 0-61 Access to Main Menu w/o Password is set to [0] Full access, then this parameter is ignored.
Option
Name
[0]*
Full access
[1]
LCP: Read only
[3]
Bus: Read only
[5]
All: Read only
Parameter 0-67 Bus Password Access
Table 40: Parameter 0-67 Bus Password Access
0-67 Bus Password Access
Default value: 0
Conversion index: 0
Use this parameter to unlock the drive via fieldbus or VLT® Motion Control Tool MCT 10.
58 | Danfoss A/S © 2022.12
Description
No access to parameters is allowed via fieldbus and/or FC standard bus.
Read-only function for parameters on LCP, fieldbus, or FC standard bus.
No access from LCP, fieldbus, or FC standard bus is allowed.
N O T I C E
Parameter type: Range, -9999 - 9999
Data type: Int16
Parameter type: Option
Data type: Uint8
Description
Disables password defined in parameter 0-65 Personal Menu Password.
Prevent unauthorized editing of Quick Menu parameters.
Read-only functions for Quick Menu parameters on fieldbus and/or FC standard bus.
Read-only function for Quick Menu parameters on LCP, fieldbus, or FC standard bus.
Parameter type: Range, 0 - 9999
Data type: Uint16
Parameter Descriptions
Setup: 1 setup
Change during operation: True
Setup: 1 setup
Change during operation: True
Setup: All setups
Change during operation: True
AU275636650261en-000101 / 130R0334

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents