VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[21]
Target inverse
[22]
Digital out 27
[23]
Digital out 29
[24]
Digital out X30/6
[25]
Digital out X30/7
[26]
Home sensor
[27]
Touch sensor
[28]
Position vir. mas-
ter
[29]
Set master home
Danfoss A/S © 2022.12
Description
This option is only available with software version 48.XX.
Changes the sign of the set target position. For example, if the set target is 1000, the activation of
this option changes the value to -1000.
This option is only available with software version 48.XX.
Accuracy of the home position depends on the delay in transferring the signals.
The home sensor is connected via fieldbus master.
This option is only available with software version 48.XX.
Accuracy of touch probe positioning depends on the delay in transferring the signals.
The touch sensor is connected via fieldbus master.
This option is only available with software version 48.XX.
Activates position-controlled virtual master when [9] Positioning or [10] Synchronization is selected
in parameter 1-00 Configuration Mode. When the option is selected, the following occurs:
Target position is set by Fieldbus Pos Ref or preset target is as defined in parameter 3-20 Preset
Target.
Speed is set relative to parameter 3-27 Virtual Master Max Ref by the source selected in parame-
ter 3-15 Reference Resource 1 or fieldbus REF1.
Acceleration and deceleration are set as defined in parameter group 3-6* Ramp 3.
This option is only available with software version 48.XX.
Sets the actual master position as defined in parameter 17-88 Master Home Position.
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
AU275636650261en-000101 / 130R0334 | 281
Parameter Descriptions