VLT AutomationDrive FC 301/302
Programming Guide
Parameter 42-54 Ramp Down Time
Table 1402: Parameter 42-54 Ramp Down Time
42-54 Ramp Down Time
Default value: 1 s
Conversion index: 0
Ramp-down time for the start ramp.
5.31.7 42-7* SMS
Parameter 42-70 Activation
Table 1403: Parameter 42-70 Activation
42-70 Activation
Default value: [0] Inactive
Conversion index: -
Option
[0]*
[1]
Parameter 42-71 Cut Off Speed
Table 1404: Parameter 42-71 Cut Off Speed
42-71 Cut Off Speed
Default value: 1500 RPM
Conversion index: 67
Maximum allowed speed.
5.31.8 42-8* Status
Parameter 42-80 Safe Option Status
Table 1405: Parameter 42-80 Safe Option Status
42-80 Safe Option Status
Default value: 0
Conversion index: 0
Shows the safety option status word as a hexadecimal value.
Parameter 42-81 Safe Option Status 2
Table 1406: Parameter 42-81 Safe Option Status 2
42-81 Safe Option Status 2
Default value: 0
Conversion index: 0
Shows the safety option status word 2 as a hexadecimal value. For example, it contains DI1, DI2, and blank initial state status.
676 | Danfoss A/S © 2022.12
Parameter type: Range, 0.1 - 3600 s
Data type: Uint16
Parameter type: Option
Data type: Uint8
Name
Inactive
Active
Parameter type: Range, 120 - 20000 RPM
Data type: Uint16
Parameter type: Range, 0 - 4294967295
Data type: Uint32
Parameter type: Range, 0 - 2147483647
Data type: Uint32
Parameter Descriptions
Setup: All setups
Change during operation: False
Setup: 2 setups
Change during operation: False
Description
Setup: 2 setups
Change during operation: False
Setup: All setups
Change during operation: True
Setup: 1 setup
Change during operation: True