5.2.5 1-3* Adv. Motor Data

The following parameters are only available in FC 302:
-
Parameter 1-37 d-axis Inductance (Ld)
-
Parameter 1-38 q-axis Inductance (Ld)
-
Parameter 1-40 Back EMF at 1000 RPM
-
Parameter 1-44 d-axis Inductance Sat. (LdSat)
-
Parameter 1-45 q-axis Inductance Sat. (LqSat)
-
Parameter 1-49 q-axis Inductance Sat. Point
This parameter group contains parameters related to:
Motor nameplate load compensations.
Application load type.
Electronic brake function for quick stop/hold of the motor.
Ensure that the motor data in parameter 1-30 Stator Resistance (Rs) to parameter 1-39 Motor Poles matches the motor. The default
settings are based on standard motor values. If the motor parameters are not set correctly, a malfunction of the drive system may
occur. If the motor data is unknown, running an AMA (automatic motor adaptation) is recommended. See parameter 1-29 Automatic
Motor Adaptation (AMA).
Parameter groups 1-3* Adv. Motor Data and 1-4* Adv. Motor Data II cannot be adjusted while the motor is running.
A simple check of the X
+ X
1
motor no load current. [VL-L/sqrt(3)]/INL = X
motors, it is highly recommended to perform this check.
P 1-33
P 1-30
I
1
R
X
1#
s
U
1
P 1-36
R
Fe
Illustration 30: Motor Equivalent Diagram of an Asynchronous Motor
Parameter 1-30 Stator Resistance (Rs)
Table 84: Parameter 1-30 Stator Resistance (Rs)
1-30 Stator Resistance (Rs)
Default value: Size related
Conversion index: -4
This parameter cannot be adjusted while the motor is running.
Set the line-to-common stator resistance value. Enter the value from a motor datasheet or perform an AMA on a cold motor.
Danfoss A/S © 2022.12
N O T I C E
N O T I C E
sum value is to divide the line-to-line motor voltage by the sqrt(3) and divide this value by the
h
+ X
. These values are important to magnetize the motor properly. For high-pole
1
h
P 1-34
X'
2 #
P 1-35
P 1-31
X
R'
h
r
Parameter type: Range, 0.0140 - 140.0000 Ohm
Data type: Uint32
N O T I C E
Parameter Descriptions
Setup: All setups
Change during operation: False
AU275636650261en-000101 / 130R0334 | 81