Danfoss VLT AutomationDrive FC 301 Programming Manual page 215

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[199]
RS Flipflop 7
[221]
IGBT-cooling
[222]
Homing OK
[223]
On target
[224]
Position limit
[225]
Position error
[226]
Touch on target
[227]
Touch activated
[228]
Touch sensor found
Danfoss A/S © 2022.12
Description
See parameter group 13-1* Comparators.
Use this option for handling the overcurrent trips. When the drive detects an overcurrent condi-
tion, it shows alarm 13, Overcurrent and triggers a reset. If the overcurrent condition occurs 3
times in a row, the drive shows alarm 13, Overcurrent and initiates a 3 minute delay before the
next reset.
This option is available only with software version 48.XX.
Homing is completed with the selected homing function (parameter 17-80 Homing Function).
This option is available only with software version 48.XX.
Positioning is completed and the on target signal is sent when the actual position is within pa-
rameter 3-05 On Reference Window for the duration of parameter 3-09 On Target Time and the
actual speed does not exceed parameter 3-05 On Reference Window.
This option is available only with software version 48.XX.
The position error exceeds the value in parameter 4-71 Maximum Position Error for the time set in
parameter 4-72 Position Error Timeout.
This option is available only with software version 48.XX.
The position is outside the limits set in parameter 3-06 Minimum Position and parameter 3-07
Maximum Position.
This option is available only with software version 48.XX.
Target position is reached in touch probe position mode.
This option is available only with software version 48.XX.
Touch probe positioning active. The drive monitors the touch probe sensor input.
This option is available only with software version 48.XX.
The touch sensor has been detected.
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
N O T I C E
AU275636650261en-000101 / 130R0334 | 215