VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[104]
Torque rel to limit
[105]
Torque relate to
rated
[106]
Power
[107]
Speed
[108]
Torque
[109]
Max out freq
[113]
PID clamped out-
put
[117]
Shaft power
[119]
Torque % lim
[123]
Speed both dir
[135]
Torq.% nom 4–
20mA
[139]
Bus ctrl
[141]
Bus ctrl t.o.
[147]
Main act val
[158]
Motor Volt.
Parameter 36-51 Terminal X49/9 Digital Output
Table 1337: Parameter 36-51 Terminal X49/9 Digital Output
36-51 Terminal X49/9 Digital Output
Default value: [0] No operation
Conversion index: –
Option
Name
[0]*
No operation
[1]
Control ready
[2]
Drive ready
650 | Danfoss A/S © 2022.12
Description
20 mA  ×  22 A
  =  11 . 46 mA
38 . 4 A
When the normal motor current is equal to 20 mA, the output setting of parameter 6-52 Terminal
42 Output Max Scale is:
I
×  100
38 . 4  ×  100
VLT, MAX 
  =  
I
22
Motor, Nom
The torque setting is related to the setting in parameter 4-16 Torque Limit Motor Mode.
The torque is related to the motor torque setting.
Taken from parameter 1-20 Motor Power [kW].
Taken from parameter 3-03 Maximum Reference. 20 mA equals the value in parameter 3-03 Maxi-
mum Reference.
Torque reference related to 160% torque.
0 Hz = 0 mA, parameter 4-19 Max Output Frequency = 20 mA.
The torque setting is related to the motor torque setting.
An output value set from fieldbus process data. The output works independently of internal func-
tions in the drive.
Parameter 4-54 Warning Reference Low defines the behavior of the analog output in case of field-
bus timeout.
Parameter type: Option
Data type: Uint8
  =  175 %
Setup: All setups
Change during operation: True
Parameter Descriptions
Description
AU275636650261en-000101 / 130R0334

Advertisement