Parameter 40-44 Fault Log: DC Link Voltage
Table 1360: Parameter 40-44 Fault Log: DC Link Voltage
40-44 Fault Log: DC Link Voltage
Default value: 0 V
Conversion index: 0
View the DC-link voltage when the logged event occurred.
Parameter 40-45 Fault Log: Control Word
Table 1361: Parameter 40-45 Fault Log: Control Word
40-45 Fault Log: Control Word
Default value: 0
Conversion index: 0
View the control word sent from the drive when the logged event occurred.
Parameter 40-46 Fault Log: Status Word
Table 1362: Parameter 40-46 Fault Log: Status Word
40-46 Fault Log: Status Word
Default value: 0
Conversion index: 0
View the status word sent from the drive when the logged event occurred.
5.30.4 40-5* Advanced Control Settings
Parameters for configuring the advanced motor control settings.
Parameter 40-50 Flux Sensorless Model Shift
Table 1363: Parameter 40-50 Flux Sensorless Model Shift
40-50 Flux Sensorless Model Shift
Default value: Size related
Conversion index: -
Use this parameter to enable or disable the shifting between flux model 1 and flux model 2 at low speed. See also parameter 1-66
Min. Current at Low Speed.
Option
[0]
[1]
Parameter 40-51 Flux Sensorless Corr. Gain
Table 1364: Parameter 40-51 Flux Sensorless Corr. Gain
40-51 Flux Sensorless Corr. Gain
Default value: Size related
Conversion index: -1
Adjust the flux correction gain used at low speed.
Danfoss A/S © 2022.12
Parameter type: Range, 0 - 10000 V, Array [10]
Data type: Uint16
Parameter type: Range, 0 - 65535, Array [10]
Data type: V2
Parameter type: Range, 0 - 65535, Array [10]
Data type: V2
Parameter type: Option
Data type: Uint8
Name
Off
On
Parameter type: Range, 0.1 - 200.0
Data type: Uint32
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: True
Description
Setup: All setups
Change during operation: True
AU275636650261en-000101 / 130R0334 | 665