VLT AutomationDrive FC 301/302
Programming Guide
Parameter 30-83 Speed PID Proportional Gain
Table 1094: Parameter 30-83 Speed PID Proportional Gain
30-83 Speed PID Proportional Gain
Default value: Size related
Conversion index: -4
Enter the speed controller proportional gain. Quick control is obtained at high amplification. However, if amplification is too great,
the process may become unstable.
Parameter 30-84 Process PID Proportional Gain
Table 1095: Parameter 30-84 Process PID Proportional Gain
30-84 Process PID Proportional Gain
Default value: Size related
Conversion index: -3
Enter the process controller proportional gain. Quick control is obtained at high amplification. However, if amplification is too great,
the process may become unstable.
Parameter 30-85 Motor Frequency
Table 1096: Parameter 30-85 Motor Frequency
30-85 Motor Frequency
Default value: Size related
Conversion index: -1
Changing this parameter affects the settings of other parameters.
Select the motor frequency from the motor nameplate data.
Parameter 30-88 System Inertia
Table 1097: Parameter 30-88 System Inertia
Parameter 30-88 System Inertia
Default value: Size related
Conversion index: -6
This parameter is only available with software version 48.82 and newer.
Enables setting the system inertia with 6 decimals for small motors (parameter 1-69 System Inertia only has 4 decimals).
5.23.6 30-9* Wifi LCP
Parameters for configuring the wireless LCP 103.
584 | Danfoss A/S © 2022.12
Parameter type: Range, 0 - 1
Data type: Uint32
Parameter type: Range, 0 - 10
Data type: Uint16
Parameter type: Range, 20.0 - 1000.0 Hz
Data type: Uint32
N O T I C E
Parameter type: Range, 0.000000 - 2000.000000 [kgm
Data type: Uint32
N O T I C E
Parameter Descriptions
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: False
2
]
Setup: All setups
Change during operation: False