VLT AutomationDrive FC 301/302
Programming Guide
View the power section. The readout is identical to the drive power field of the type code definition, characters 7–10.
Parameter 15-42 Voltage
Table 787: Parameter 15-42 Voltage
15-42 Voltage
Default value: 0
Conversion index: 0
View the voltage. The readout is identical to the drive power field of the type code definition, characters 11-12.
Parameter 15-43 Software Version
Table 788: Parameter 15-43 Software Version
15-43 Software Version
Default value: 0
Conversion index: 0
View the combined SW version (or package version) consisting of power SW and control SW.
Parameter 15-44 Ordered Typecode String
Table 789: Parameter 15-44 Ordered Typecode String
15-44 Ordered Typecode String
Default value: 0
Conversion index: 0
View the type code string used for reordering the drive in its original configuration.
Parameter 15-45 Actual Typecode String
Table 790: Parameter 15-45 Actual Typecode String
15-45 Actual Typecode String
Default value: 0
Conversion index: 0
View the actual type code string.
Parameter 15-46 Frequency Converter Ordering No
Table 791: Parameter 15-46 Frequency Converter Ordering No
15-46 Frequency Converter Ordering No
Default value: 0
Conversion index: 0
View the 8-digit code number used for reordering the drive in its original configuration. To restore the order number after the pow-
er card exchange, see parameter 14-29 Service Code.
Parameter 15-47 Power Card Ordering No
Table 792: Parameter 15-47 Power Card Ordering No
15-47 Power Card Ordering No
Default value: 0
Conversion index: 0
490 | Danfoss A/S © 2022.12
Parameter type: Range, 0 - 20
Data type: VisStr[20]
Parameter type: Range, 0 - 5
Data type: VisStr[5]
Parameter type: Range, 0 - 40
Data type: VisStr[40]
Parameter type: Range, 0 - 40
Data type: VisStr[40]
Parameter type: Range, 0 - 8
Data type: VisStr[8]
Parameter type: Range, 0 - 8
Data type: VisStr[8]
Parameter Descriptions
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
AU275636650261en-000101 / 130R0334