VLT AutomationDrive FC 301/302
Programming Guide
Set-up
1
2
3
4
Set-up
1
2
3
4
Set-up
1
2
3
4
Set-up
1
2
3
4
Illustration 25: Edit Setup
Parameter 0-12 This Set-up Linked to
Table 13: Parameter 0-12 This Set-up Linked to
0-12 This Set-up Linked to
Default value: [0] Not linked
Conversion index: –
To enable conflict-free changes from 1 setup to another during operation, link setups containing parameters which are not change-
able during operation. The link ensures synchronizing of the not changeable during operation-parameter values when moving from
1 setup to another during operation. Not changeable during operation-parameters can be identified by the label FALSE in the
Change during operation field. Parameter 0-12 This Set-up Linked to is used by [9] Multi set-up in parameter 0-10 Active Set-up. Multi
setup is used to move from 1 setup to another during operation.
Option
[0]*
[1]
Danfoss A/S © 2022.12
P 0-11
P 0-11
P 0-11
PLC Fieldbus
P 0-11
Parameter type: Option
Data type: Uint8
Name
Not linked
Set-up 1
Parameter Descriptions
Setup: All setups
Change during operation: False
Description
AU275636650261en-000101 / 130R0334 | 39