Danfoss VLT AutomationDrive FC 301 Programming Manual page 515

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Parameter 16-96 Maintenance Word
Table 909: Parameter 16-96 Maintenane Word
16-96 Maintenane Word
Default value: 0
Conversion index: 0
Readout of the preventive maintenance word. The bits reflect the status for the programmed preventive maintenance events in
parameter group 23-1* Maintenance. 13 bits show combinations of all the possible items:
Bit 0: Motor bearings
Bit 1: Pump bearings
Bit 2: Fan bearings
Bit 3: Valve
Bit 4: Pressure transmitter
Bit 5: Flow transmitter
Bit 6: Temperature transmitter
Bit 7: Pump seals
Bit 8: Fan belt
Bit 9: Filter
Bit 10: Drive cooling fan
Bit 11: Drive system health check
Bit 12: Warranty
Bit 13: Maintenance text 0
Bit 14: Maintenance text 1
Bit 15: Maintenance text 2
Bit 16: Maintenance text 3
Bit 17: Maintenance text 4
The following table details the display of the maintenance word.
Table 910: Maintenance Word
Position 4⇒
Valve
Position 3⇒
Pump seals
Position 2⇒
Drive system health check
Position 1⇒
0
hex
1
hex
2
hex
3
hex
4
hex
5
hex
6
hex
7
hex
Danfoss A/S © 2022.12
Parameter type: Range, 0 - 4294967295
Data type: Uint32
Fan bearings
Temperature transmitter
Drive cooling fan
+
+
+
+
Parameter Descriptions
Setup: All setups
Change during operation: False
Pump bearings
Motor bearings
Flow transmitter
Pressure transmitter
Filter
Fan belt
Warranty
+
+
+
+
+
+
+
+
AU275636650261en-000101 / 130R0334 | 515