VLT AutomationDrive FC 301/302
Programming Guide
Parameter 12-95 Inactivity Timeout
Table 665: Parameter 12-95 Inactivity Timeout
12-95 Inactivity Timeout
Default value: 120
Conversion index: 0
Applies to parameter 12-94 Broadcast Storm Protection, if the broadcast storm protection also includes multicast telegrams.
Parameter 12-96 Port Config
Table 666: Parameter 12-96 Port Config
12-96 Port Config
Default value: Size related
Conversion index: –
Enable or disable the port-mirroring function. The function is used for troubleshooting with a network analyzer tool.
Option
[0]
[1]
[2]
[10]
[11]
[254]
[255]
Parameter 12-97 QoS Priority
Table 667: Parameter 12-97 QoS Priority
12-97 QoS Priority
Default value: Size related
Conversion index: 0
Each index sets the DSCP value of different types of QoS prioritized messages.
Parameter 12-98 Interface Counters
Table 668: Parameter 12-98 Interface Counters
12-98 Interface Counters
Default value: 4000
Conversion index: 0
This parameter is read-only. Advanced interface counters from a built-in switch can be used for low-level troubleshooting. The pa-
rameter shows a sum of port 1 + port 2.
Danfoss A/S © 2022.12
Parameter type: Range, 0 - 3600
Data type: Uint16
Parameter type: Option
Data type: Uint8
Name
Normal
Mirror port 1 to 2
Mirror port 2 to 1
Port 1 disabled
Port 2 disabled
Mirror int. port to 1
Mirror int. port to 2
Parameter type: Range, 0 - 63
Data type: Int8
Parameter type: Range, 0 - 4294967295
Data type: Uint32
Parameter Descriptions
Setup: 2 setups
Change during operation: True
Setup: 2 setups
Change during operation: True
Description
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True