Option
[0]
[1]
Parameter 42-11 Encoder Resolution
Table 1373: Parameter 42-11 Encoder Resolution
42-11 Encoder Resolution
Default value: [1024]
Conversion index: 0
Encoder or proximity switch resolution of the encoder connected to the MCB 150 TTL and MCB 151 HTL.
Parameter 42-12 Encoder Direction
Table 1374: Parameter 42-12 Encoder Direction
42-12 Encoder Direction
Default value: [0] Clockwise
Conversion index: -
Option
[0]*
[1]
Parameter 42-13 Gear Ratio
Table 1375: Parameter 42-13 Gear Ratio
42-13 Gear Ratio
Default value: 1
Conversion index: 0
Ratio between motor speed and encoder speed.
Only use when the drive is gear-mounted.
Parameter 42-14 Feedback Type
Table 1376: Parameter 42-14 Feedback Type
42-14 Feedback Type
Default value: [0] With direction info
Conversion index: -
Option
Name
[0]*
With direction info
[1]
Without direction info
Danfoss A/S © 2022.12
Name
None
Safe option
Parameter type: Range, 1 - config. dependent
Data type: Uint16
Parameter type: Option
Data type: Uint8
Name
Clockwise
Counterclockwise
Parameter type: Range, 0.0001 - 1000.0000
Data type: Uint32
N O T I C E
Parameter type: Option
Data type: Uint8
Parameter Descriptions
Description
Setup: 1 setup
Change during operation: False
Setup: 1 setup
Change during operation: False
Description
Setup: 1 setup
Change during operation: False
Setup: 1 setup
Change during operation: False
Description
AU275636650261en-000101 / 130R0334 | 669