VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[15]
Select preset ref 5
[16]
Select preset ref 6
[17]
Select preset ref 7
[18]
Select ramp 1
[19]
Select ramp 2
[20]
Select ramp 3
[21]
Select ramp 4
[22]
Run
[23]
Run reverse
[24]
Stop
[25]
Qstop
[26]
Dcstop
[27]
Coast
[28]
Freeze output
[29]
Start timer 0
[30]
Start timer 1
[31]
Start timer 2
[32]
Set digital out A low
[33]
Set digital out B low
[34]
Set digital out C low
[35]
Set digital out D low
[36]
Set digital out E low
[37]
Set digital out F low
[38]
Set digital out A high
[39]
Set digital out B high
[40]
Set digital out C high
[41]
Set digital out D high
[42]
Set digital out E high
[43]
Set digital out F high
[60]
Reset Counter A
[61]
Reset Counter B
Danfoss A/S © 2022.12
Description
Selects preset reference 5. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
Selects preset reference 6. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
Selects preset reference 7. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
Selects ramp 1.
Selects ramp 2.
Selects ramp 3.
Selects ramp 4.
Issues a start command to the drive.
Issues a start reverse command to the drive.
Issues a stop command to the drive.
Issues a quick stop command to the drive.
Issues a DC stop command to the drive.
The drive coasts immediately. All stop commands including the coast command stop the SLC.
Freezes the output frequency of the drive.
Starts timer 0, see parameter 13-20 SL Controller Timer for further description.
Starts timer 1, see parameter 13-20 SL Controller Timer for further description.
Starts timer 2, see parameter 13-20 SL Controller Timer for further description.
Any output with smart logic output A is low.
Any output with smart logic output B is low.
Any output with smart logic output C is low.
Any output with smart logic output D is low.
Any output with smart logic output E is low.
Any output with smart logic output F is low.
Any output with smart logic output A is high.
Any output with smart logic output B is high.
Any output with smart logic output C is high.
Any output with smart logic output D is high.
Any output with smart logic output E is high.
Any output with smart logic output F is high.
Resets counter A to 0.
Resets counter B to 0.
Parameter Descriptions
AU275636650261en-000101 / 130R0334 | 419