Parameter 18-24 Marker Pos. Offset
Table 984: Parameter 18-24 Marker Pos. Offset
18-24 Marker Pos. Offset
Default Value: 0
Parameter Type: Range, -2147483648 - 2147483647 [pu]
Conversion Index: 0
Data Type: Int32
This parameter is only available in software version 48.8X.
Shows the position difference between master marker and follower marker in position units as defined in parameter group 17-0*
Position Scaling. The value is calculated by: Marker Pos. Offset = Master marker position – Follower marker position.
Parameter 18-25 Latched Actual Pos.
Table 985: Parameter 18-25 Latched Actual Pos.
18-25 Latched Actual Pos.
Default value: 0
Parameter type: Range, -2147483648 - 2147483647 [pu]
Conversion index: 0
Data type: Int32
This parameter is only available in software version 48.8X.
Shows the actual position latched by the latest detected sensor, that is home sensor, touch sensor, or follower marker.
Parameter 18-26 Actual Velocity [pu/s]
Table 986: Parameter 18-26 Actual Velocity [pu/s]
18-26 Actual Velocity [pu/s]
Default value: 0
Parameter type: Range, -2147483648 - 2147483647 [pu]
Conversion index: 0
Data type: Int32
This parameter is only available in software version 48.8X.
Shows the actual speed in position units per second.
Parameter 18-27 Safe Opt. Speed
Table 987: Parameter 18-27 Safe Opt. Speed
18-27 Safe Opt. Speed
Default value: 0 RPM
Conversion index: 67
Shows the speed that the drive estimates and sends to the VLT® Safety Option MCB 15X.
542 | Danfoss A/S © 2022.12
N O T I C E
N O T I C E
N O T I C E
Parameter type: Range, -30000 - 30000 RPM
Data type: Int32
Parameter Descriptions
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True
Setup: All setups
Change during operation: True