Danfoss VLT AutomationDrive FC 301 Programming Manual page 279

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT AutomationDrive FC 301/302
Programming Guide
Option
Name
[232]
In power lim. gen.
[233]
In power limit
[234]
Emcy m. OPR unexpected
[254]
Testing emcy mode
Parameter 8-14 Configurable Control Word CTW
Table 505: Parameter 8-14 Configurable Control Word CTW
8-14 Configurable Control Word CTW
Default value: [1] Profile default
Conversion index: –
This is an array parameter with 16 elements, 1 element for each bit in range 0–15. Each of the bits can be configured to any of the
following options.
Option
Name
[0]
None
[1]*
Profile default
[2]
CTW valid, active
low
[3]
Safe option reset
[4]
PID error inverse
[5]
PID reset I part
[6]
PID enable
[7]
External interlock
[10]
Bit 10 = 0>CTW
timeout
Danfoss A/S © 2022.12
Description
This option is only available in FC 302.
See parameter group 4-8* Power Limit. Use this option in generating mode only.
This option is only available in FC 302.
See parameter group 4-8* Power Limit. Use this option in both motor and generating
modes.
Emergency mode is not operating as expected, for example, live zero monitoring on an
analog input is activated.
Emergency mode was activated in a special test mode where the drive stops on all
alarms.
Parameter type: Option, Array [16]
Data type: Uint8
Description
The drive ignores the information in this bit.
Dependent on the profile set in parameter 8-10 Control Profile.
If set to 1, the drive ignores the remaining bits of the control word.
This function is only available in bits 12–15 of the control word if a safety option is mounted in the
drive. The reset is executed on a 0⇒1 transition and resets the safety option as set in parameter
42-24 Restart behavior.
Inverts the resulting error from the process PID controller. Available only if parameter 1-00 Configu-
ration Mode is set to [6] Surface Winder, [7] Extended PID Speed OL, or [8] Extended PID Speed CL.
Resets the I-part of the process PID controller. Equivalent to parameter 7-40 Process PID I-part Reset.
Available only if parameter 1-00 Configuration Mode is set to [6] Surface Winder, [7] Extended PID
Speed OL, or [8] Extended PID Speed CL.
Enables the extended process PID controller. Equivalent to parameter 7-50 Process PID Extended
PID. Available only if parameter 1-00 Configuration Mode is set to [6] Surface Winder, [7] Extended
PID Speed OL, or [8] Extended PID Speed CL.
N O T I C E
N O T I C E
Setup: 2 setups
Change during operation: True
AU275636650261en-000101 / 130R0334 | 279