feedback source in parameter 1-02 Flux Motor Feedback Source, parameter 7-00 Speed PID Feedback Source, or parameter 7-90 Position
PI Feedback Source.
Parameter 17-68 Raw Abs. Pos. Low
Table 939: Parameter 17-68 Raw Abs. Pos. Low
17-68 Raw Abs. Pos. Low
Default value: 0
Conversion index: 0
This parameter is only available with software version 48.9X.
Shows the least significant 32 bits of the position value read from an absolute encoder connected to VLT® Encoder Input MCB 102.
MCB 102 must be selected as feedback source in parameter 1-02 Flux Motor Feedback Source, parameter 7-00 Speed PID Feedback
Source, or parameter 7-90 Position PI Feedback Source.
Parameter 17-69 Raw Abs. Pos. High
Table 940: Parameter 17-69 Raw Abs. Pos. High
17-69 Raw Abs. Pos. High
Default value: 0
Conversion index: 0
This parameter is only available with software version 48.9X.
Shows the most significant 32 bits of the position value read from an absolute encoder connected to VLT® Encoder Input MCB 102.
MCB 102 must be selected as feedback source in parameter 1-02 Flux Motor Feedback Source, parameter 7-00 Speed PID Feedback
Source, or parameter 7-90 Position PI Feedback Source.
5.17.7 17-7* Position Scaling
Parameters in this group define how the drive scales and handles the position values.
Parameter 17-70 Position Unit
Table 941: Parameter 17-70 Position Unit
17-70 Position Unit
Default value: [0] pu
Conversion index: -
Select the physical unit for showing the position values on the LCP.
Option
Name
Description
[0]*
pu
Position unit.
[1]
m
Meters.
[2]
mm
Millimeters
[3]
inc
Increments.
[4]
°
Degrees.
Danfoss A/S © 2022.12
Parameter type: Range, 0 - 2147483647
Data type: Uint32
N O T I C E
Parameter type: Range, 0 - 2147483647
Data type: Uint32
N O T I C E
Parameter type: Option
Data type: Uint8
Parameter Descriptions
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False
Setup: All setups
Change during operation: False