Sign In
Upload
Manuals
Brands
Danfoss Manuals
DC Drives
FC 300
Danfoss FC 300 Manuals
Manuals and User Guides for Danfoss FC 300. We have
17
Danfoss FC 300 manuals available for free PDF download: Design Manual, Programming Manual, Operating Instructions Manual, Operating Instruction, Instruction Manual, Manual
Danfoss FC 300 Design Manual (309 pages)
VLT AutomationDrive
Brand:
Danfoss
| Category:
Media Converter
| Size: 7 MB
Table of Contents
Table of Contents
1
How to Read this Design Guide
5
Approvals
5
Symbols
6
Abbreviations
6
Definitions
7
Power Factor
11
Introduction to FC 300
13
Disposal Instructions
13
Software Version
13
CE Conformity and Labeling
14
What Is Covered
14
Danfoss VLT Adjustable Frequency Drive and CE Labeling
15
Compliance with EMC Directive 89/336/EEC
15
Air Humidity
15
Aggressive Environments
16
Vibration and Shock
16
Control Principle
16
FC 300 Controls
17
FC 301 Vs. FC 302 Control Principle
18
Control Structure in VVC Plus
19
Control Structure in Flux Sensorless (FC 302 Only)
20
Control Structure in Flux with Motor Feedback
21
Internal Current Control in VVC+ Mode
22
Local (Hand On) and Remote (Auto On) Control
22
Reference Handling
25
Scaling of References and Feedback
26
Dead Band Around Zero
27
Speed PID Control
31
The Following Parameters Are Relevant for the Speed Control
31
Process PID Control
34
Ziegler Nichols Tuning Method
39
General Aspects of EMC Emissions
40
EMC Test Results (Emission, Immunity)
42
Required Compliance Levels
43
EMC Immunity
43
Galvanic Isolation (PELV)
45
Ground Leakage Current
45
Selection of Brake Resistor
47
Control with Brake Function
49
Control of Mechanical Brake
50
Smart Logic Control
51
Extreme Running Conditions
52
Motor Thermal Protection
53
Safe Stop of FC 300
54
FC 300 Selection
55
Electrical Data
55
General Specifications
60
Efficiency
66
Acoustic Noise
67
Peak Voltage on Motor
67
Derating for Ambient Temperature - Data Valid for ≤ 10 HP [7.5 Kw]
68
Derating for Low Air Pressure
68
Derating for Running at Low Speed
68
Derating for Installing Long Motor Cables or Cables with Larger Cross-Section
69
Temperature-Dependent Switch Frequency
69
Mechanical Dimension
70
Options and Accessories
72
Mounting Option Modules in Slot B
72
General Purpose Input Output Module MCB 101
73
Encoder Option MCB 102
75
Resolver Option MCB 103
77
Relay Option MCB 105
79
Back-Up Option (Option D)
81
Brake Resistors
81
Remote Mounting Kit for LCP
81
IP 21/IP 4X/ TYPE 1 (NEMA 1) Enclosure Kit
82
IP 21/Type 1 Enclosure Kit
82
LC Filters
82
How to Order
83
Drive Configurator
83
Ordering Form Type Code
84
Ordering Numbers
87
How to Install
93
Mechanical Installation
93
Accessory Bag ≤ 10 HP [7.5 Kw]
93
Safety Requirements of Mechanical Installation
96
Field Mounting
96
Electrical Installation
97
Removal of Knockouts for Extra Cables
97
Connection to Line Supply and Grounding
97
Motor Connection
100
Motor Cables
102
Electrical Installation of Motor Cables
102
Fuses
103
Access to Control Terminals
105
Control Terminals (FC 301)
105
Electrical Installation, Control Terminals
106
Basic Wiring Example
107
Electrical Installation, Control Cables
108
Switches S201, S202, and S801
109
Final Set-Up and Test
110
Safe Stop Installation (FC 302 Only)
112
Safe Stop Commissioning Test
113
Additional Connections
114
Load Sharing
114
Installation of Load Sharing
114
Brake Connection Option
114
Relay Connection
115
Relay Output
116
Parallel Connection of Motors
116
Direction of Motor Rotation
117
Installation of Brake Cable
117
RS 485 Bus Connection
118
How to Connect a PC to the FC 300
118
The FC 300 Software Dialog
119
High Voltage Test
120
Safety Ground Connection
120
Electrical Installation - EMC Precautions
120
Use of EMC-Correct Cables
122
Grounding of Shielded/Armored Control Cables
123
Mains Supply Interference/Harmonics
124
Residual Current Device
125
Advertisement
Danfoss FC 300 Design Manual (305 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 9 MB
Table of Contents
Table of Contents
1
How to Read this Design Guide
5
Approvals
5
Symbols
6
Abbreviations
6
Definitions
7
Introduction to FC 300
13
Disposal Instruction
13
Software Version
13
Air Humidity
15
Aggressive Environments
15
Vibration and Shock
16
Control Principle
17
FC 300 Controls
17
FC 301 Vs. FC 302 Control Principle
17
Control Structure in VVC
18
Control Structure in Flux Sensorless (FC 302 Only)
19
Control Structure in Flux with Motor Feedback
19
Internal Current Control in VVC+ Mode
20
Local (Hand On) and Remote (Auto On) Control
21
Reference Handling
23
Scaling of References and Feedback
24
Dead Band Around Zero
24
Speed PID Control
29
The Following Parameters Are Relevant for the Speed Control
29
Process PID Control
31
Ziegler Nichols Tuning Method
35
EMC Test Results (Emission, Immunity)
37
EMC Immunity
38
Earth Leakage Current
40
Selection of Brake Resistor
40
Control of Mechanical Brake
42
Safe Stop of FC 300
45
Safe Stop Installation (FC 302 and FC 301 - A1 Enclosure Only)
46
Safe Stop Commissioning Test
47
FC 300 Selection
49
Electrical Data
49
General Specifications
53
Efficiency
58
Acoustic Noise
58
Peak Voltage on Motor
59
Tion
59
How to Order
63
Drive Configurator
63
Ordering Form Type Code
63
Ordering Numbers
65
How to Install
71
Mechanical Dimension
71
Mechanical Installation
73
Accessory Bag
73
Electrical Installation
76
Removal of Knockouts for Extra Cables
76
Connection to Mains and Earthing
77
Motor Connection
79
Fuses
81
Access to Control Terminals
83
Control Terminals (FC 301)
83
Electrical Installation , Control Terminals
84
Basic Wiring Example
84
Electrical Installation , Control Cables
85
Motor Cables
86
Switches S201, S202, and S801
87
Final Set-Up and Test
88
Additional Connections
90
Relay Connection
91
Relay Output
92
Parallel Connection of Motors
92
Motor Thermal Protection
93
How to Connect a PC to the FC 300
94
The FC 300 Software Dialog
94
Residual Current Device
99
Application Examples
101
Start/Stop
101
Pulse Start/Stop
101
Potentiometer Reference
102
Encoder Connection
102
Encoder Direction
102
Closed Loop Drive System
103
Programming of Torque Limit and Stop
103
Smart Logic Control Programming
104
Danfoss FC 300 Design Manual (259 pages)
0,25 kWt - 1,2 mWt
Brand:
Danfoss
| Category:
DC Drives
| Size: 32 MB
Table of Contents
Table of Contents
1
1 How to Read this Design Guide
5
Symbols
5
Abbreviations
6
Definitions
6
2 Safety and Conformity
11
Safety Precautions
11
Aggressive Environments
14
3 Introduction to Automationdrive FC
17
Product Overview
17
Control Principle
19
Automationdrive FC 300 Controls
19
Automationdrive FC 301 Vs. Automationdrive FC 302 Control Principle
20
Control Structure in VVC Plus Advanced Vector Control
21
Control Structure in Flux Sensorless (Automationdrive FC 302 Only)
22
Control Structure in Flux with Motor Feedback
22
Internal Current Control in VVC Plus Mode
23
Local (Hand On) and Remote (Auto On) Control
23
Reference Limits
26
Scaling of Preset References and Bus References
26
Scaling of Analog and Pulse References and Feedback
27
Dead Band Around Zero
27
Speed PID Control
30
Process PID Control
33
Ziegler Nichols Tuning Method
37
EMC Test Results
39
PELV - Protective Extra Low Voltage
41
Brake Functions in Automationdrive FC
43
Mechanical Holding Brake
43
Dynamic Braking
43
Selection of Brake Resistor
43
Control with Brake Function
46
Mechanical Brake Control
46
Hoist Mechanical Brake
47
Safe Stop of Automationdrive FC
51
4 Automationdrive FC 300 Selection
59
Electrical Data - 200-240
59
Electrical Data - 380-500
61
Electrical Data - 525-600
67
Electrical Data - 525-690
70
General Specifications
78
Efficiency
83
Acoustic Noise
84
Du/Dt Conditions
84
Special Conditions
89
Automatic Adaptations to Ensure Performance
96
5 How to Order
97
Drive Configurator
97
Ordering Form Type Code
98
General Purpose Input Output Module MCB
101
Encoder Option MCB
102
6 Mechanical Installation - Frame Size A, B and C
117
7 Mechanical Installation - Frame Size D, E and F
121
Pre-Installation
121
Planning the Installation Site
121
Receiving the Frequency Converter
121
Transportation and Unpacking
121
Lifting
122
Mechanical Dimensions
122
Mechanical Installation
131
Terminal Locations - Frame Size D
133
Terminal Locations - Frame Size E
135
Terminal Locations - Frame Size F
139
Cooling and Airflow
142
8 Electrical Installation
149
Connections- Frame Sizes A, B and C
149
Connection to Mains and Earthing
150
Motor Connection
153
Relay Connection
156
Connections - Frame Sizes D, E and F
157
Power Connections
157
Fuses
168
Disconnectors, Circuit Breakers and Contactors
173
Motor Thermal Protection
175
Parallel Connection of Motors
175
Motor Insulation
177
Motor Bearing Currents
177
Control Cables and Terminals
178
Control Cable Routing
178
Control Terminals
180
Switches S201, S202, and S801
180
Electrical Installation, Control Terminals
181
Basic Wiring Example
182
Electrical Installation, Control Cables
183
Relay Output
185
Additional Connections
186
How to Connect a PC to the Frequency Converter
187
The Automationdrive FC 300 PC Software
188
Residual Current Device
193
Final Setup and Test
194
Advertisement
Danfoss FC 300 Design Manual (200 pages)
Brand:
Danfoss
| Category:
Controller
| Size: 8 MB
Table of Contents
Table of Contents
1
1 How to Read this Design Guide
5
Approvals
5
Symbols
5
Abbreviations
6
Definitions
6
2 Safety and Conformity
13
Safety Precautions
13
3 Introduction to FC
19
Product Overview
19
Control Principle
21
FC 300 Controls
21
FC 301 Vs. FC 302 Control Principle
22
Control Structure in Vvcplus
23
Control Structure in Flux Sensorless (FC 302 Only)
24
Control Structure in Flux with Motor Feedback
24
Internal Current Control in Vvcplus Mode
25
Local (Hand On) and Remote (Auto On) Control
25
Reference Handling
28
Scaling of References and Feedback
29
Dead Band Around Zero
29
Speed PID Control
32
Process PID Control
35
Ziegler Nichols Tuning Method
40
EMC Immunity
44
Ground Leakage Current
46
Selection of Brake Resistor
46
Mechanical Brakecontrol
49
Hoist Mechanical Brake
51
Smart Logic Control
52
Safe Stop of the FC
54
Safe Stop Installation (FC 302 and FC 301 - A1 Enclosure Only)
56
Safe Stop Commissioning Test
57
4 FC 300 Selection
61
MG.33.B9.22 - VLT ® Is a Registered Danfoss Trademark
61
Electrical Data
61
General Specifications
75
Efficiency
81
Acoustic Noise
81
Du/Dt Conditions
82
Automatic Adaptations to Ensure Performance
90
5 How to Order
91
Drive Configurator
91
Ordering Form Type Code
91
6 How to Install
101
Mechanical Dimension
101
Mechanical Installation
105
Relay Option MCB
105
Electrical Installation
108
Connection to Line Power and Grounding
110
Motor Connection
111
Fuses
116
Control Terminals
121
Electrical Installation, Control Terminals
121
Basic Wiring Example
124
Electrical Installation, Control Cables
124
Motor Cables
125
Switches S201, S202, and S801
126
Additional Connections
130
Relay Connection
131
Relay Output
132
Parallel Connection of Motors
132
Motor Thermal Protection
133
How to Connect a PC to the FC 300
135
The FC 300 PC Software
136
Residual Current Device
142
Danfoss FC 300 Programming Manual (234 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 3 MB
Table of Contents
Table of Contents
1
1 Introduction
3
Approvals
3
Symbols
3
Abbreviations
4
Definitions
4
2 How to Programme
11
The Graphical and Numerical Local Control Panels
11
How to Programme on the Graphical LCP
11
The LCD-Display
12
Quick Transfer of Parameter Settings between Multiple Frequency Converters
14
Display Mode
16
Display Mode - Selection of Read-Outs
16
Parameter Set-Up
17
Quick Menu Key Functions
17
Main Menu Mode
20
Parameter Selection
20
Changing Data
20
Changing a Text Value
20
Changing a Group of Numeric Data Values
21
Infinitely Variable Change of Numeric Data Value
21
Changing a Data Value,Step-By-Step
22
Read-Out and Programming of Indexed Parameters
22
How to Programme on the Numerical Local Control Panel
23
Local Control Keys
24
Initialisation to Default Settings
25
Parameters: Operation and Display
27
Parameters: Load and Motor
42
Parameters: Brakes
63
Parameters: Reference/Ramps
70
Parameters: Limits/Warnings
86
Parameters: Digital In/Out
94
Parameters: Analog In/Out
112
Parameters: Controllers
121
Parameters: Communications and Options
127
Parameters: Profibus
134
Parameters: Devicenet CAN Fieldbus
145
Parameters: Smart Logic Control
153
Parameters: Special Functions
171
Parameters: Drive Information
181
Parameters: Data Read-Outs
190
Parameters: Encoder Input
198
Parameter Lists
202
Index
229
Danfoss FC 300 Programming Manual (204 pages)
Brand:
Danfoss
| Category:
Media Converter
| Size: 4 MB
Table of Contents
Table of Contents
1
Introduction
3
Approvals
3
Symbols
3
Abbreviations
3
Definitions
4
Electrical Wiring - Control Cables
8
How to Programme
12
The Graphical and Numerical Local Control Panels
12
How to Programme on the Graphical LCP
12
The LCD-Display
13
Display Mode
15
Display Mode - Selection of Read-Outs
15
Parameter Set-Up
17
Quick Menu Key Functions
17
Main Menu Mode
19
Parameter Selection
19
Infinitely Variable Change of Numeric Data Value
20
Read-Out and Programming of Indexed Parameters
20
How to Programme on the Numerical Local Control Panel
20
Local Control Keys
22
Initialisation to Default Settings
22
Parameter Descriptions
23
Parameters: 0-** Operation and Display
23
Parameters: 1-** Load and Motor
33
Parameters: 2-** Brakes
47
Parameters: 3-** Reference/Ramps
52
Parameters: 4-** Limits/Warnings
62
Parameters: 5-** Digital In/Out
67
Parameters: 6-** Analog In/Out
85
Parameters: 7-** Controllers
94
Parameters: 8-** Communications and Options
99
Parameters: 9-** Profibus
108
Parameters: 10-** Devicenet CAN Fieldbus
114
Parameters: 12-** Ethernet
118
Parameters: 13-** Smart Logic Control
122
Parameters: 14-** Special Functions
134
Parameters: 15-** Drive Information
142
Parameters: 16-** Data Read-Outs
146
Parameters: 18-** Data Readouts
154
Parameters: 30-** Special Features
154
Parameters: 35-** Sensor Input Option
157
Parameter Lists
159
Troubleshooting
190
Warnings/Alarm Messages
190
Index
199
Danfoss FC 300 Programming Manual (205 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 3 MB
Table of Contents
Table of Contents
1
1 Introduction
3
Approvals
3
Symbols
3
Abbreviations
4
Definitions
4
2 How to Programme
11
The Graphical and Numerical Local Control Panels
11
How to Programme on the Graphical LCP
11
The LCD-Display
11
Display Mode
14
Display Mode - Selection of Read-Outs
14
Parameter Set-Up
16
Quick Menu Key Functions
16
Main Menu Mode
19
Parameter Selection
19
Infinitely Variable Change of Numeric Data Value
21
Read-Out and Programming of Indexed Parameters
21
How to Programme on the Numerical Local Control Panel
22
Local Control Keys
23
Initialisation to Default Settings
24
Parameters: Operation and Display
26
Parameters: Load and Motor
39
Parameters: Brakes
55
Parameters: Reference/Ramps
61
Parameters: Limits/Warnings
74
Parameters: Digital In/Out
80
Parameters: Analog In/Out
94
Parameters: Controllers
101
Parameters: Communications and Options
105
Parameters: Profibus
110
Parameters: Devicenet CAN Fieldbus
119
Parameters: Smart Logic Control
126
Parameters: Special Functions
142
Parameters: Drive Information
150
Parameters: Data Read-Outs
157
Parameters: Encoder Input
164
Parameter Lists
167
3 Troubleshooting
193
Danfoss FC 300 Operating Instructions Manual (100 pages)
VLT AutomationDrive 0.25-75 kW
Brand:
Danfoss
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
5
1 Introduction
8
Purpose of the Manual
10
Additional Resources
10
Product Overview
10
Internal Controller Functions
10
Frame Sizes and Power Ratings
12
2 Installation
13
Installation Site Check List
13
Frequency Converter and Motor Pre-Installation Check List
13
Mechanical Installation
13
Cooling
13
Lifting
14
Mounting
14
Tightening Torques
14
Electrical Installation
15
Requirements
17
Earth (Grounding) Requirements
17
Leakage Current (>3.5 Ma)
18
Grounding Using Shielded Cable
18
Motor Connection
18
AC Mains Connection
19
Control Wiring
19
Access
19
Control Terminal Types
20
Wiring to Control Terminals
21
Using Screened Control Cables
21
Control Terminal Functions
22
Terminal 53 and 54 Switches
22
Mechanical Brake Control
23
Serial Communication
23
Safe Stop
24
Terminal 37 Safe Stop Function
25
Safe Stop Commissioning Test
27
3 Start up and Functional Testing
28
Pre-Start
28
Safety Inspection
28
Applying Power
30
Basic Operational Programming
30
Jumper Terminals 12 and
31
Asynchronous Motor Setup
31
PM Motor Setup in VVC Plus
31
Automatic Motor Adaptation
32
Check Motor Rotation
33
Check Encoder Rotation
33
Local-Control Test
34
System Start up
34
4 User Interface
35
Local Control Panel
35
LCP Layout
35
Setting LCP Display Values
36
Display Menu Keys
36
Navigation Keys
37
Operation Keys
37
Back up and Copying Parameter Settings
37
Uploading Data to the LCP
38
Downloading Data from the LCP
38
Restoring Default Settings
38
Recommended Initialisation
38
Manual Initialisation
38
Danfoss FC 300 Manual (61 pages)
CANopen
Brand:
Danfoss
| Category:
DC Drives
| Size: 1 MB
Table of Contents
Table of Contents
1
Safety Note
4
Introduction
5
About this Manual
5
Technical Overview
5
Assumptions
6
Hardware
6
Background Knowledge
6
FC 300-Related Literature
6
Abbreviations
6
How to Install
9
Cabling
9
Cable Lengths
9
Cable Specifications
9
EMC Precautions
10
Connection of the Cable Screen
11
Earth Connection
11
Canopen Connection
12
Canopen Termination
12
Installation of Option in Drive
13
How to Configure the System
14
Set the Canopen Address
14
Set the Canopen Address Via Parameter 10-02 Drive Node ID
14
Set the Canopen Baud Rate
14
Set the Canopen Baud Rate Via Parameter 10-01 Baudrate Select
14
Configure the Network
15
Network Management NMT
15
1005H, 1006H, 1007H Synchronization Object (SYNC)
15
1017H Producer Heartbeat Time
15
1014H, 1015H Emergency Object (EMCY)
16
Configure the FC 300
17
VLT Parameters
17
Leds
17
How to Control the FC300
18
Device Profile
18
Communication in Canopen
18
Communication Profile Area (1000H-1Fffh)
20
Communication Object Overview
20
1000H Device Type
21
1001H Error Register
21
1002H Manufacturer Status Register
21
1003H Predefined Error Field
21
1005H COB-ID Sync Message Object
22
1008H Manufacturer Device Name
22
1009H Manufacturer Hardware Version
22
100Ah Manufacturer Software Version
22
100Ch Guard Time
22
100Dh Life Time Factor
22
1010H Store Parameters
22
1011H Restore Default Parameters
23
1014H COB ID Emergency Object
23
1018H Identity Object
23
DSP 402 Control Profile
24
Control Word According to DSP 402 Profile. (Par. 8-10 = DSP 402 Profile)
24
Status Word According to DSP 402 Profile. (Par. 8-10 = DSP 402 Profile)
25
Standardised Device Profile Area
27
Danfoss FC Control Profile
28
Bus Speed Reference Value
31
Process Data Objects (PDO)
32
Structure of PDO COB-ID Entry
32
PDO Usage
32
PDO Transmission Modes
33
PDO Triggering Modes
33
PDO Services
33
Receive PDO
34
Receive PDO (M): Control Word
34
Receive PDO: Target Velocity
35
St Receive PDO: PCD 0 and PCD 1
35
Nd Receive PDO: PCD 2, PCD 3, PCD 4, PCD 5
35
Transmit PDO
36
Transmit PDO
37
22Nd Transmit PDO
37
Danfoss Specific Objects (2000H-5Fffh)
38
Danfoss FC 300 Operating Instructions Manual (78 pages)
Frequency Converter
Brand:
Danfoss
| Category:
Media Converter
| Size: 4 MB
Table of Contents
Table of Contents
1
How to Read These Operating Instructions
3
Approvals
4
Symbols
5
Abbreviations
5
Safety Instructions and General Warning
7
Software Version: 3.XX
7
High Voltage Warning
8
Safety Instructions
8
Avoid Unintended Start
8
Safe Stop of FC 302
8
IT Mains
9
How to Install
11
How to Get Started
11
Accessory Bag ≤ 7.5 Kw
12
Mechanical Installation
13
Electrical Installation
15
Removal of Knockouts for Extra Cables
15
Connection to Mains and Earthing
15
Motor Connection
17
Motor Cables
19
Fuses
20
Access to Control Terminals
22
Electrical Installation, Control Terminals
22
Basic Wiring Example
23
Electrical Installation, Control Cables
24
Switches S201, S202, and S801
25
Tightening Torque
25
Final Set-Up and Test
26
Additional Connections
28
24 V Back-Up Option
28
Mounting of Option Modules in Slot B (MCB 101 and MCB 102)
29
General Purpose Input Output Module MCB 101
29
Encoder Option MCB 102
31
Load Sharing
32
Relay Option MCB 105
33
Brake Connection Option
36
Relay Connection
36
Control of Mechanical Brake
37
Motor Thermal Protection
37
How to Programme
39
The Local Control Panel
39
How to Programme on the Graphical Local Control Panel
39
Quick Transfer of Parameter Settings
42
Reset to Default Setting
43
Adjust Display Contrast
43
Connection Examples
44
Start/Stop
44
Pulse Start/Stop
44
Speed Up/Down
44
Danfoss FC 300 Instruction Manual (77 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 2 MB
Table of Contents
Table of Contents
1
How to Read this Instruction Manual
3
Approvals
4
Symbols
5
Abbreviations
6
Safety Instructions and General Warning
7
Software Version
7
High Voltage Warning
8
Safety Instructions
8
High Start Torque
8
Safe Stop of FC 302
8
Mains
9
How to Install
11
How to Get Started
11
Accessory Bag
12
Mechanical Installation
13
Electrical Installation
15
Connection to Mains and Grounding
15
Motor Connection
16
Motor Cables
17
Fuses
18
Access to Control Terminals
20
Electrical Installation, Control Terminals
20
Control Terminals
21
Electrical Installation, Control Cables
22
Switches S201, S202, and S801
23
Tightening Torque
23
Final Set-Up and Test
24
Additional Connections
26
24 V Backup Option
26
Encoder Option MCB 102
27
Relay Option MCB 105
29
Loadsharing
31
Brake Connection Option
31
Relay Connection
32
Control of Mechanical Brake
33
Thermal Motor Protection
33
How to Program
35
The Local Control Panel
35
How to Program on the Graphical Local Control Panel
35
Quick Transfer of Parameter Settings
38
Reset to Default Setting
39
Adjust Display Contrast
39
Connection Examples
40
Start/Stop
40
Pulse Start/Stop
40
Speed Up/Slow down
41
Potentiometer Reference
41
Basic Parameters
42
Parameter Lists
45
General Specifications
61
Troubleshooting
67
Warnings/Alarm Messages
67
Index
75
Danfoss FC 300 Operating Instruction (82 pages)
Brand:
Danfoss
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
1
How to Read These Operating Instructions
3
Approvals
5
Symbols
5
Abbreviations
5
Safety Instructions and General Warning
7
Software Version
8
High Voltage Warning
8
Safety Instructions
8
Avoid Unintended Start
9
Safe Stop of FC 300
9
Safe Stop Installation (FC 302 and FC 301 - A1 Enclosure Only)
10
IT Mains
10
How to Install
11
How to Get Started
11
Accessory Bag
13
Mechanical Installation
14
Electrical Installation
17
Removal of Knockouts for Extra Cables
17
Connection to Mains and Earthing
18
Motor Connection
20
Fuses
22
Access to Control Terminals
24
Electrical Installation, Control Terminals
24
Connection Examples
25
Start/Stop
25
Pulse Start/Stop
26
Speed Up/Down
26
Potentiometer Reference
26
Electrical Installation, Control Cables
27
Switches S201, S202, and S801
28
Final Set-Up and Test
29
Additional Connections
31
Control of Mechanical Brake
31
Motor Thermal Protection
31
How to Programme
33
The FC 300 Graphical and Numerical LCP
33
How to Programme on the Graphical Local Control Panel
33
How to Programme on the Numerical Local Control Panel
34
Quick Setup
36
Parameter Lists
39
Parameter Selection
40
General Specifications
67
Warnings and Alarms
73
Warnings/Alarm Messages
73
Danfoss FC 300 Instruction Manual (64 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 1 MB
Table of Contents
Table of Contents
1
How to Read this Instruction Manual
3
Approvals
5
Symbols
5
Abbreviations
6
Safety Instructions and General Warning
7
High Voltage Warning
7
Safety Instructions
7
High Start Torque
7
IT Mains
8
How to Install
9
How to Get Started
9
Accessory Bag
10
Mechanical Installation
11
Electrical Installation
12
Connection to Mains and Grounding
12
Motor Connection
13
Motor Cables
14
Fuses
15
Access to Control Terminals
17
Electrical Installation, Control Terminals
17
Control Terminals
18
Electrical Installation, Control Cables
19
Switches S201, S202, and S801
20
Tightening Torque
21
Final Set-Up and Test
21
Additional Connections
23
Backup Option
23
Load Sharing
23
Brake Connection Option
24
Relay Connection
25
Control of Mechanical Brake
25
Thermal Motor Protection
26
How to Program
27
The Local Control Panel
27
How to Program on the Local Control Panel
27
Quick Transfer of Parameter Settings
29
Reset to Default Setting
29
Adjust Display Contrast
30
How to Connect a PC to the FC 300
30
The FC 300 Software Dialog
30
Connection Examples
31
Start/Stop
31
Pulse Start/Stop
31
Speed Up/Slow down
31
Potentiometer Reference
31
Basic Parameters
32
Parameter Lists
35
General Specifications
49
Troubleshooting
55
Warnings/Alarm Messages
55
Index
63
Danfoss FC 300 Instruction Manual (68 pages)
Brand:
Danfoss
| Category:
DC Drives
| Size: 1 MB
Table of Contents
Table of Contents
1
How to Read this Instruction Manual
3
Approvals
4
Symbols
5
Abbreviations
5
Safety Instructions and General Warning
7
Software Version
8
High Voltage Warning
8
Safety Instructions
8
High Start Torque
8
Safe Stop of FC 302
9
IT Line
9
How to Install
11
How to Get Started
11
Accessory Bag ≤ 10 HP [7.5 Kw]
12
Mechanical Installation
14
Electrical Installation
15
Removal of Knockouts for Extra Cables
15
Connection to Line Supply and Grounding
15
Motor Connection
18
Motor Cables
20
Fuses
21
Access to Control Terminals
23
Electrical Installation, Control Terminals
23
Basic Wiring Example
24
Connection Examples
25
Start/Stop
25
Pulse Start/Stop
25
Speed Up/Slow down
26
Potentiometer Reference
26
Electrical Installation, Control Cables
27
Switches S201, S202, and S801
28
Tightening Torque
28
Final Set-Up and Test
29
Additional Connections
31
Control of Mechanical Brake
31
Motor Thermal Protection
31
How to Program
33
Quick Setup
34
Parameter Lists
37
Parameter Selection
38
General Specifications
53
Warnings and Alarms
59
Index
67
Danfoss FC 300 Operating Instructions Manual (60 pages)
Brand:
Danfoss
| Category:
Media Converter
| Size: 2 MB
Table of Contents
Table of Contents
1
How to Read These Operating Instructions
3
Approvals
4
Symbols
5
Abbreviations
5
Safety Instructions and General Warning
7
High Voltage Warning
7
Safety Instructions
7
Avoid Unintended Start
7
IT Mains
9
How to Install
11
How to Get Started
11
Accessory Bag
12
Mechanical Installation
12
Electrical Installation
13
Connection to Mains and Earthing
13
Motor Connection
15
Motor Cables
16
Fuses
17
Access to Control Terminals
18
Electrical Installation, Control Terminals
18
Control Terminals
19
Electrical Installation, Control Cables
20
Switches S201, S202, and S801
21
Tightening Torque
21
Final Set-Up and Test
22
Additional Connections
23
24 V Back-Up Option
23
Load Sharing
24
Brake Connection Option
24
Relay Connection
25
Control of Mechanical Brake
25
Motor Thermal Protection
26
How to Programme
27
The Local Control Panel
27
How to Programme on the Local Control Panel
27
Quick Transfer of Parameter Settings
29
Reset to Default Setting
29
Adjust Display Contrast
30
How to Connect a PC to the FC 300
30
The FC 300 Software Dialogue
30
Connection Examples
31
Start/Stop
31
Pulse Start/Stop
31
Speed Up/Down
31
Potentiometer Reference
31
Basic Parameters
32
Parameter Lists
34
General Specifications
47
Troubleshooting
53
Warnings/Alarm Messages
53
Index
59
Danfoss FC 300 Manual (54 pages)
CANopen
Brand:
Danfoss
| Category:
DC Drives
| Size: 1 MB
Table of Contents
Table of Contents
1
S a F E T y N O T E
3
A B O U T T H I S M a N U a L
4
T E C H N I C a L O V E R V I E W
4
A S S U M P T I O N S
5
H a R D W a R E
5
B a C K G R O U N D K N O W L E D G E
5
F C 3 0 0 - R E L a T E D L I T E R a T U R E
5
C I a C O N F O R M a N C E
5
A B B R E V I a T I O N S
6
H O W T O I N S T a L L
7
T H E C a N O P E N O P T I O N
7
L E D B E H a V I O U R
8
M O D U L E S T a T U S ( M S ) , R E D
8
N E T W O R K S T a T U S ( N S ) , G R E E N
8
H a R D W a R E S W I T C H E S
8
C a B L I N G
9
C a B L E S P E C I F I C a T I O N S
9
C O N N E C T I O N O F T H E C a B L E S C R E E N
9
E a R T H C O N N E C T I O N
9
C a N O P E N C O N N E C T O R
9
C a N O P E N T E R M I N a T I O
10
E M C P R E C a U T I O N
11
H O W T O I N S T a L L O P T I O N I N F R E Q U E N C y C O N V E R T E
12
H O W T O C O N F I G U R E T H E S y S T E
13
O B J E C T M O D E
13
C O M M U N I C a T I O N I N C a N O P E
14
C O B - I D E N T I F I E R S ( I
14
C O N T R O L L I N G T H E N E T W O R
15
N E T W O R K M a N a G E M E N T ( N M
15
E R R O R C O N T R O
16
E M E R G E N C y O B J E C T ( E M C
16
B U S E R R O R C O U N T E R
17
S D O C O M M U N I C a T I O
18
S a V I N G O D E N T R I E
18
R E S T O R I N G O D E N T R I E
18
S E T T I N G U P C a N O P E N M a S T E
19
E D S F I L
19
C O N F I G U R I N G T H E C a N O P E N M a S T E
19
C O N F I G U R I N G T H E F C 3 0 0
21
L T P a R a M E T E R
21
H O W T O C O N T R O L T H E F
22
P D O T R a N S M I S S I O N M O D E
24
P D O T R I G G E R I N G M O D E
24
I N H I B I T T I M
24
E V E N T T I M E
24
C O N T R O L P R O F I L
25
D S P 4 0 2 S T a T E M a C H I N
25
D S P 4 0 2 C O N T R O L P R O F I L
27
D a N F O S S F C C O N T R O L P R O F I L
30
R E F E R E N C E H a N D L I N
34
H O W T O a C C E S S F C 3 0 0 P a R a M E T E R
35
D a N F O S S S P E C I F I C O B J E C T S ( 2 0 0 0 H - 5 F F F
35
Danfoss FC 300 Operating Instructions Manual (45 pages)
Interbus
Brand:
Danfoss
| Category:
DC Drives
| Size: 0 MB
Table of Contents
Table of Contents
1
2 Introduction
5
About this Manual
5
Technical Overview
5
Assumptions
5
Hardware
5
Background Knowledge
5
Abbreviations
6
3 How to Install
7
Cabling
7
Installation of Option
8
How to Install
9
Leds
10
Configure the FC 300
11
4 How to Configure the System
13
Configure the Interbus Network
13
5 How to Control the FC 300
17
Process Data
17
The Drivecom State Machine
21
Drivecom 21 Control Profile
24
Danfoss FC Control Profile
26
6 How to Access the FC 300 Parameters
31
PCP Communication
31
7 Parameters
33
Data Types Supported by FC 300
39
8 Troubleshooting
41
LED Behaviour Stopped Interbus Comm
43
Index
44
Advertisement
Related Products
Danfoss FC 300 Interbus
Danfoss VLT FC 322
Danfoss VLT AutomationDrive FC 361
Danfoss FC 300 Profibus
Danfoss FC 300 Series
Danfoss VLT AutomationDrive FC 303
Danfoss VLT AutomationDrive EZ FC 321
Danfoss FC322 Series
Danfoss VLT AutomationDrive FC 301/302
Danfoss FC103-110-250Kw
Danfoss Categories
Controller
DC Drives
Thermostat
Control Unit
Air Compressor
More Danfoss Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL