Xe Interfaces - Allied Telesis SwitchBlade x3100 Series Manual

Release 14.2 - issue 2
Table of Contents

Advertisement

Overview

2.4 XE Interfaces

2.4.1 Overview
Interface management includes state management, configuration, alarms, audits and optics query.
The only provisionable attribute for an XE interface is FLOW, which can be either ON or OFF, and defaults to
OFF.
The XE interfaces can also be configured for either CUSTOMER or NETWORK direction.
There are two attributes that can be set:
FLOW - (ON, OFF)
DIRECTION - (CUSTOMER, NETWORK) - The only option for the XE card is NETWORK.
2.4.2 Example Output
Following is an example output.
show interface eth:0.0
--- XE Interfaces ---
Interface.......................... 0.0
Type............................... XE
State.............................. UP-UP-Online
Description........................ voip2 ring primary Uplink
Remote ID.......................... <none>
External Profile................... <none>
Card Type.......................... XE4
Provisioning
Provisioning Profile............ AutoProv
Flow Control.................... Off
Remote Monitoring............... On
Actual
Direction....................... Network
Port Speed...................... 10 Gbps
Physical Address................ EC:CD:6D:03:26:55
Software Reference for SwitchBlade x3100 Series Switches (Interface Management)
GE Interfaces
2-7

Advertisement