Sample Command Output - Allied Telesis SwitchBlade x3100 Series Manual

Release 14.2 - issue 2
Table of Contents

Advertisement

Introduction
There are two, replaceable opto-coupler modules on the back of the chassis, labeled as SBxOCPLR. There is
one for PSU slots A and C, and the other is for PSU slots B and D, as indicated on the back of the chassis.
These opto-coupler modules are not hot- swappable and affect the control plane between the CFCs and the
PSUs. Each opto-coupler has a green power LED that is illuminated under normal circumstances. In the event
that an opto-coupler module is faulty, the CFCs will not be able to communicate with the associated PSUs.
Therefore, as part of troubleshooting an alarm on the PSUs, the user should visually inspect the associated
opto-coupler on the back of the chassis to ensure that it is functioning.
PSUs can be queried from the CLI using SHOW PSU. PSUs cannot be disabled or enabled but can be created
and destroyed. The CREATE PSU command assumes that slot A and B are for POE type PSUs, and slots C and
D are for system PSUs, so the user doesn't have to specify the PSU type on the command. PSUs can be
destroyed from the system database using DESTROY PSU, but only if they are not physically present. The sys-
tem will only allow one system PSU to be destroyed under any circumstance, but will allow both POE PSUs to
be destroyed if not physically present. PSUs are always auto provisioned upon insertion regardless of system
provisioning mode.

1.15.1.4 Sample Command Output

The following are examples of power supply unit commands.
The Amps and Watts are shown as "-" or "<unknown>" if the hardware version of the PSU does not
Note:
support querying this information.
show psu
--- Power Supply Units ---
Slot Type
State Temp(C)
---- ------ ----- -------
A
POE
UP-UP 38
B
POE
UP-UP 38
C
System UP-UP 33
show PSU full
--- Power Supply Units ---
Slot.................................. A
Type.................................. POE
State................................. UP-UP-Online
Hardware
Model Number........................ AT-SBx3165
1-206
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
Power Management

Advertisement

Table of Contents
loading

Table of Contents