Introduction
1.12 LED Management
1.12.1 Introduction
On the SBx3100, the LEDs have the following attributes:
Color - Green or amber
•
State - Solid, flashing, or off
•
1.12.2 CFC200
The CFC 200 has:
2 slot status LEDs, labeled per slot number (0-11) on the faceplate
•
one power LED, labeled "PSU" on the faceplate
•
one activity LED, labeled "M/S" (for Master/Slave) on the faceplate
•
one Fan Status LED, labeled "FAN" on the faceplate
•
one management Ethernet port LED, labeled "L/A" (for Link/Activity) on the faceplate
•
one SD card LED, labeled "SD" on the faceplate, to show status of the removable SD memory card
•
The slot status LEDs on the CFC are physically controlled by the cards in the slots, not by the CFC.
Note:
1.12.3 PSU
Each PSU card has 3 LEDs
One input AC power LED, labeled "AC" on the faceplate
•
One output DC power LED, labeled "DC" on the faceplate
•
One fault LED, labeled "FAULT" on the faceplate
•
If any provisioned PSU is in failed state, then the single PSU LED on the CFC is flashing amber.
Note:
1.12.4 XE4
The XE4 card has four green LEDs, one for each port, labeled L/A (for Link/Activity) on the faceplate. The LED
is on when the link is up, and blinking when the link has activity. Disabling the XE interface turns the LED off,
regardless of whether a fiber is present.
1.12.5 GE24POE
The GE24POE card has two LEDs per port. One port LED is used to indicate activity (green for a 1Gbps link,
yellow for a 10/100 Mbps link, and flashing for activity). The second port LED is used to indicate PoE status
(green for PoE active, solid yellow for power fault conditions and flashing yellow for insufficient power condi-
1-182
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
:
Introduction