Set Log Output - Allied Telesis SwitchBlade x3100 Series Manual

Release 14.2 - issue 2
Table of Contents

Advertisement

Introduction

SET LOG OUTPUT

Syntax
SET LOG OUTPUT=outputid
[ { CLI [ FORMAT={ FULL | MSGONLY | SUMMARY } ] |
CONSOLE [ FORMAT={ FULL | MSGONLY | SUMMARY } ] |
SYSLOG { [ SERVER={ ipaddress | hostname } ] }
{ [ FACILITY={ 0..7 | DEFAULT } ] |
[ CRITICALFACILITY={ 0..7 | DEFAULT } ]
[ MAJORFACILITY={ 0..7 | DEFAULT } ]
[ MINORFACILITY={ 0..7 | DEFAULT } ]
[ INFOFACILITY={ 0..7 | DEFAULT } ] } |
FILE=unit:filename [ FORMAT={ FULL | MSGONLY | SUMMARY } ] } ]
Used to change the management log output destination settings. By default, if no cate-
Description
gory, severity or format options are specified, the management log filter is set to match
all logs.
The following table gives the range of values for each option that can be specified with
Options
this command and a default value (if applicable).
1-178
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
Option
Description
OUTPUT
The outputid that was created.
CLI
The output will go to the Command Console.
FORMAT can be:
- FULL displays the entire log message.
- SUMMARY displays only the category, timestamp, and
log type.
- MSGONLY displays only the log message.
CONSOLE
The FORMAT meanings are the same as for the CLI.
SYSLOG
The SERVER that will receive the management log
SERVER
stream
FACILITY
The log facility that all levels of syslogs are sent to.
Refer to RFC3164 for details on the SYSLOG protocol.
CRITICAL-
The log facility that critical syslogs are sent to. The pos-
FACILITY
sible values are 0-7, indicating LOCAL0-LOCAL7 or
DEFAULT.
MAJORFA-
The log facility that major syslogs are sent to. The pos-
CILITY
sible values are 0-7, indicating LOCAL0-LOCAL7 or
DEFAULT.
Logging Procedures
Default Value
2 (DEFAULT)
LOCAL2
LOCAL2