Allied Telesis SwitchBlade x3100 Series Manual page 102

Release 14.2 - issue 2
Table of Contents

Advertisement

Introduction
The following procedure shows the commands used for adding an SNTP server, enabling SNTP, and modifying
the system timezone.
TABLE 1-10
Step
Command
Review the default SNTP settings before configuring
SHOW SNTP
1
SNTP Configuration
------------------------------------------------------------------------------
Status
Local IP
Last Update
Last Delta
Last Status
SNTP Server
------------------------------------------------------------------------------
No SNTP Server Configured
SNTP Statistics
------------------------------------------------------------------------------
Requests Sent
Responses Received
Set up the configuration for SNTP. These commands are normally issued during system setup
>ENABLE TELNET SERVER
2
>ADD IP INTERFACE=MGMT IPADDRESS=10.52.70.14 SUBNETMASK=255.255.255.0
CARD=ACTCFC GATEWAY=10.52.70.1 IFNAME=MGMT MANAGEMENT=Yes
>ENABLE IP INTERFACE=MGMT
Add the SNTP server (by specifying an IP address or hostname)
ADD SNTP SERVER=192.43.244.18
3
Enable the SNTP server
ENABLE SNTP
4
Note the results
1-72
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
Configuration Procedure for SNTP
Off
10.52.70.14
-
-
-
0
0
Description (Optional)
Specifies the hostname or IP address of the SNTP
server that the SBx3112 system will use.
Activates the SNTP so that the SBx3112 will be
able to synchronize its clock with the SNTP clock.
Configuring SNTP

Advertisement

Table of Contents
loading

Table of Contents