Allied Telesis SwitchBlade x3100 Series Manual page 347

Release 14.2 - issue 2
Table of Contents

Advertisement

Configuring LAG
The following procedure shows the commands used to create the LAG shown in
TABLE 4-3
Step
Command
Ensure that physical interfaces that you wish to combine into a LAG have matching provisioning attributes (e.g., VLAN
configuration, speed, duplex, auto-negotiation, direction, etc.)
Show the first two interfaces (0.8 and 0.9) designated for the LAG
show interface 0.8 full
1
--- GE Interfaces ---
Interface.......................... 0.8
Type............................... GE
State.............................. UP-UP-Online
Description........................ <none>
Remote ID.......................... <none>
External Profile................... <none>
Card Type.......................... GE24SFP
Provisioning
Provisioning Profile............ AutoProv (*)
Direction....................... Network
Auto Negotiation................ On
Speed........................... Auto
Duplex.......................... Full
Flow Control.................... Auto
Remote Monitoring............... On
Actual
Direction....................... Network
Physical Address................ EC:CD:6D:03:6E:F7
Speed........................... 1 Gbps
Duplex.......................... Full
Flow Control.................... Off
VLAN Information
Acceptable Frame Types.......... All
Ingress Filtering............... On
TPID............................ 0x8100
TAGALL.......................... Off
Dynamic MAC Learning Limit...... 0
Untagged VLAN................... 1500
Packet Statistics
Octets..........................
Unicast Packets.................
Discarded Packets...............
Errored Packets.................