XE4 Card Attributes
RESTART CARD
Syntax
RESTART CARD={ slot-list | INACTCFC | ACTCFC } [ COLD ] [ FORCE ]
Performs a restart of the software running on the specified card. For the active CFC card,
Description
the entire system is affected and all cards are restarted.
The following table gives the range of values for each option that can be specified with
Options
this command and a default value (if applicable).
Option
CARD
INACTCFC
ACTCFC
COLD
FORCE
RESTART Card=INACTCFC COLD FORCE
Example
Software Reference for SwitchBlade x3100 Series Switches (Setting Up the Switch)
Description
The slot number of the card(s) to be reset. The list must
not include the slots for the ACTCFC or INACTCFC
The inactive CFC as determined by the system.
For a dual CFC, the
inactive CFC as determined by
the system. Otherwise the single active CFC
For the active CFC card, a COLD restart - resets the
CFC and all other cards in the shelf - reboots and re ini-
tializes the software on the CFC - runs out of service
diagnostics on the CFC if previously scheduled through
use of the DIAGNOSE CARD command - reloads con-
figuration data from the system database - manages
recovery of the remaining cards in the shelf
For the inactive CFC card, a COLD restart - changes
the operational state to DOWN, if not already DOWN
- performs a hardware reset on the card - reboots and
re initializes the software - runs out of service diagnos-
tics - reloads configuration data - restores the opera-
tional state to UP if the administrative state is UP,
including data initialization and initiation of defect moni-
toring
Performs the reset without the confirmation message.