Configuring the GE24POE Card

SHOW POE INTERFACE

Syntax
SHOW POE INTERFACE [ ={ type:id-range | id-range | ifname-list |
ALL } ] [ FULL ]
Displays the PoE attributes and settings for one or more interfaces.
Description
The following table gives the range of values for each option that can be specified with
Options
this command and a default value (if applicable).
Example
When a specific interface is included, the SHOW POE INTER-
FACE command shows the main attributes for the specified
interface. With the FULL option, this command shows the con-
figuration options and the actual status.
officer SEC>> SHOW POE INTERFACE=1.*,2.0
--- POE Power Status ---
PoE
Interface State
--------- -------- -------- ----- -------------- ---------- ----------
1.0
1.1
1.2
1.3
1.4
1.5
2.0
officer SEC>> SHOW POE INTERFACE=1.1 FULL
Interface............................. 1.0
POE State............................. Enabled
Priority.............................. Low
Power Limit........................... CLASS
Actual
3-16
Software Reference for SwitchBlade x3100 Series Switches (Power over Ethernet (PoE))
Option
Description
INTERFACE
A logical representation of one or more physical ports
type:id-range - the type of available ports, such as
ETH:7.0 or a range (ETH:8.0-8.9)
id-range - used with type (type:id) to query the physical
ports; the numerical identifier of the interface
ifname-list - list of interface names, if not numerical
ALL - all applicable interfaces in the system
FULL
Shows full information for the specified command.
POE
Priority Limit Power Status
Disabled Low
Enabled
High
Enabled
Low
Enabled
Critical 10.0W
Enabled
Critical
Enabled
High
Enabled
High
--- POE Power Status ---
Power Status........................ Powered
Class............................... 3 (15.4W)
Power............................... 4.3W
Voltage............................. 50.1V
Current............................. 86mA
Class
7.0W
Disabled
2 (7W)
CLASS
Powered
3 (15.4W)
15.0W
No PD Detected -
Fault Present
0 (15.4W)
5.5W
Powered
2 (7W)
5.0W
Disabled
4 (30W)
CLASS
Disabled
-
Configuration Guidelines
Default Value
Actual
0W
8.7W
0W
0W
6.4W
0W ...