Allied Telesis SwitchBlade x3100 Series Manual page 889

Release 14.2 - issue 2
Table of Contents

Advertisement

Interface Diagnostics
DIAGNOSE CARD
Syntax
DIAGNOSE CARD={ slot-list | ACTCFC | INACTCFC | ALL }
{ INSERVICE | OUTOFSERVICE }
The DIAGNOSE CARD command runs a series of diagnostic tests on the specified card
Description
or list of cards. Currently, out-of-service diagnostics are the only diagnostics supported
For all service cards and the inactive CFC, the cardmust be in the administratively
DOWN for the diagnostics torun (See DISABLE CARD).
The following table gives the range of values for each option that can be specified with
Options
this command and a default value (if applicable).
Option
CARD
Example
DIAGNOSE CARD
Software Reference for SwitchBlade x3100 Series Switches (Alarms and Troubleshooting)
Description
Specifies the slot number for the card for which to dis-
play diagnostics.
slot-list - list of specific cards to be tested (single slot,
comma-separated list of slots, dash range of slots, com-
bination of dash and comma-separated slots)
For the active CFC card, the diagnos-
ACTCFC -
tics are not run immediately, but are instead
scheduled to run during the next restart of the
active CFC. The restart is requested using the
RESTART CARD command.
INACTCFC - As with Line Cards, the INACTCFC must
have an Operational state of DOWN.
ALL - Not supported
INSERVICE - In service cards (Admin and Operational
state of UP) - Not supported
OUTOFSERVICE - Out-of-service cards (Operational
state of DOWN)
=INACTCFC
Troubleshooting the SBx3112 (Diagnostics)
Default Value
8-17

Advertisement

Table of Contents
loading