Example
ADD INTERFACE=ETH:11.0 RMONALERT PACKETS ABSOLUTE INTERVAL=5 RIS-
INGTHRESHOLD=100000 FALLINGTHRESHOLD=10000
7-102
Software Reference for SwitchBlade x3100 Series Switches (Network Management)
Option
Description
INTERVAL
The period of time between data collections in seconds
(2..3600). May contain a single value for the interface(s)
or a number of data collection entries may be created at
one time by providing a list of intervals.
RISING-
RISING threshold - the upper limit of a monitored sta-
THRESHOLD
tistic before an event is generated. When the rising
threshold is crossed, a management log is generated
along with an SNMP trap.
FALLING-
FALLING threshold - the lower limit of a monitored sta-
THRESHOLD
tistic before an event is generated. When the falling
threshold is crossed, a management log is generated
along with an SNMP trap.