Allied Telesis SwitchBlade x3100 Series Manual page 447

Release 14.2 - issue 2
Table of Contents

Advertisement

Configuring EPSR
The EPSR domain name is allied
The CONTROL VLAN is 3501, the DATA VLAN is 3502
The interfaces are on 0.2 and 1.3 (separate cards)
ENHANCEDRECOVERY is turned on as the last step.
TABLE 4-17
Step
Command
Create the EPSR domain
CREATE EPSR allied MASTER
1
Create the Control VLAN and associate them with the interfaces as FRAME=TAGGED.
CREATE VLAN vid=3501
2
ADD VLAN 3501 INTERFACE 0.2 FRAME=TAGGED
ADD VLAN 3501 INTERFACE 1.3 FRAME=TAGGED
Define the interface for the EPSR domain that will be PRIMARY and SECONDARY
ADD EPSR ALLIED INTERFACE=0.2 TYPE=PRI-
3
MARY
ADD EPSR ALLIED INTERFACE=0.3 TYPE=SEC-
ONDARY
Add VLAN 3501 as the CONTROL VLAN.
ADD EPSR ALLIED VLAN=3501 TYPE=CONTROL
4
Create the DATA VLAN and add this VLAN to the interfaces.
CREATE VLAN vid=3502
5
ADD VLAN=3502 INTERFACE=0.2 frame=tagged
ADD VLAN=3502 INTERFACE=1.3 frame=tagged
Add the VLAN to the EPSR domain as the data VLAN.
ADD EPSR allied VLAN=3502 TYPE=data
6
Using the SET command, you can turn on the Enhanced Recovery feature.
SET EPSR allied ENHANCEDRECOVERY=ON
7
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
Configuration Procedure for EPSR - Configure a Master Node
Description/Notes
You can set ENHANCEDRECOVERY here or
later. Here it is Step 7.
The interfaces should be on separate cards
You will receive a warning that this may cause a
network loop if this VLAN is not configured in
an EPSR domain for the interface. Enter Y for
confirmation.
Introduction
4-127

Advertisement

Table of Contents
loading

Table of Contents