Allied Telesis SwitchBlade x3100 Series Manual page 461

Release 14.2 - issue 2
Table of Contents

Advertisement

Configuring SuperLoop
TABLE 4-19
Step
Command
show vlan
8
--- VLAN Information -------------------------------------------------------------------------
Name
--------------- ---- ---------- ------------------------------- -----------------------------
default
vlan6
vlan20
vlan200
vlan300
Set GE interfaces to the NETWORK direction
set interface 8.2 ge direction network
9
set interface 9.2 ge direction network
set interface 3.2 ge direction network
Add interfaces to the "allied-1" domain
ADD EPSR=allied-1 INTERFACE=ETH:[8.2]
10
ADD EPSR=allied-1 INTERFACE=ETH:[3.2]
Add interfaces to the "allied-2" domain
ADD EPSR=allied-2 INTERFACE=ETH:[9.2]
11
ADD EPSR=allied-2 INTERFACE=ETH:[3.2]
Add control VLAN to the "allied-1" domain
ADD EPSR=allied-1 VLAN=200 TYPE=CONTROL
12
Add the data VLANs to the "allied-1" domain
ADD EPSR=allied-1 VLAN=6 TYPE=DATA
13
ADD EPSR=allied-1 VLAN=20 TYPE=DATA
Review configuration information for the "allied-1" domain
Software Reference for SwitchBlade x3100 Series Switches (Layer Two Switching)
Configuration Procedure for SuperLoop - Peer SuperLoop Domain
VID
Forwarding Tagged Interfaces
Mode
1
Standard
<none>
6
Standard
ETH:[0.0],[3,8-9.2]
10
Standard
ETH:[3,8-9.2]
200
Standard
ETH:[3,8.2]
300
Standard
ETH:[3,9.2]
Description
Untagged Interfaces
ETH:[0.1-3],[1-2,6-7,10-11.0-3],
[3,8-9.0-1,3-23]
<none>
<none>
<none>
<none>
Configures the GE interfaces for the Network
direction.
Adds interfaces 8.2 and 3.2 to the "allied-
1" EPSR domain.
Adds interfaces 9.2 and 3.2 to the "allied-
2" EPSR domain.
Adds VLAN 200 to the "allied-1" EPSR
domain as the control VLAN.
Adds VLAN 6 to the "allied-1" EPSR
domain as a data VLAN.
Adds VLAN 20 to the "allied-1" EPSR
domain as a data VLAN.
Introduction
4-141

Advertisement

Table of Contents
loading