Show Interface Optics - Allied Telesis SwitchBlade x3100 Series Manual

Release 14.2 - issue 2
Table of Contents

Advertisement

Example Output

SHOW INTERFACE OPTICS

Syntax
SHOW INTERFACE [ ={ type: | type:id-range | id-range | ifname-list
| ALL } ] [ OPTICS ] [ FULL ]
Shows the optics data, as a subset of the data contained the SFP/XFP memory. For the
Description
user to query the optics on an interface, the card must be operationally UP but the state
of the interface does not matter, as long as the SFP/XFP module is physically present.
The following table gives the range of values for each option that can be specified with
Options
this command and a default value (if applicable).
Option
INTERFACE
OPTICS
FULL
Example
E135 - manager SEC>> SHOW INTERFACE OPTICS
--- Interface Optics ---
Port
Interface
Type
----------- ----- ------------ ---------- ---------------- -----------
10.0
-
10.1
XE
10.2
XE
10.3
XE
11.0
XE
11.1
XE
11.2
XE
11.3
XE
Software Reference for SwitchBlade x3100 Series Switches (Interface Management)
Description
The interfaces that will have information displayed.
Shows the optics specifications
Gives complete information for the interfaces specified.
Transceiver
Nominal
Type
Bit Rate
-
-
XFP
10000
XFP
10000
XFP
10000
XFP
<unknown>
XFP
10000
XFP
10000
XFP
10000
Tx/Rx Power
Temperature
-/-
0.5739/0.6255
0.5698/0.5744
0.5627/0.5619
0.0000/0.0000
0.5508/0.5579
0.6016/0.3873
0.5618/0.4203
GE Interfaces
Default Value
ALL
-
30.9 C
32.1 C
33.2 C
0.0 C
33.3 C
34.6 C
32.7 C
2-21